Table 76:
Code
SOA
(Secure On Always)
SOD
(Secure On Default)
SOS
(Secure On Sticky)
!
nn
Unn
(User-allowed Corporate
indexes)
H
(Hide Secure Status)
For example, if you want to allow the user to edit the first four Corporate secure indexes
and secure keys only, and the status of the CES-128 voice encryptor to be displayed,
enter the following into the Message 10 entry:
#$! SOSU4H0
NOTE
Manpack Transceiver 2110 series Reference Manual
Codes for controlling access to CES-128 voice encryptor options
(secure on)
Description
Enables secure mode permanently at user level. Once the transceiver enters
secure mode, it remains in secure mode during scanning events. Secure
standby mode is permitted, but is ended when PTT is pressed.
NOTE If you set SOA, you do not need to set SSR.
NOTE You can exit secure mode at admin level, if required.
Enables the default secure mode when the user presses or holds SEC.
Secure standby mode is permitted. The transceiver exits secure mode when
a call ends or during scanning, and does not automatically re-enter secure
mode when a call starts, scanning ends, or the transceiver restarts.
If you want to enable the default secure mode at startup, use the
NOTE
SOD! command.
Returns to the last-used secure on/off state when the transceiver is switched
on. Secure mode may be entered or exited at any time. The transceiver
remains in secure mode when a call ends or during scanning, if requested.
Secure standby mode is permitted and remains on until
From firmware V5.11 or later, the SOS command is not required as
NOTE
this feature is now the default behaviour in the transceiver.
Enables automatic entry to secure mode on startup of the transceiver. For
more information see
page 478, Automatic startup of secure
Sets the length of time the transceiver enters secure standby, listens for
revertives, then returns to secure mode. For more information see
Automatic standby for use with Codan
Provides the user with access to the first nn Corporate secure indexes if the
Secure Index entry or Secure Key entry in the Control List is admin locked.
Sets whether the status of the CES-128 voice encryptor is displayed on the
screen when the transceiver is not secure. By default, it is not displayed
(H1). If you want Clr Voice to be displayed when secure is off, use H0.
To limit the user to the number of indexes specified, the Secure Key and
Secure Index entries in the Control List must be admin hidden. For more
information see
page 132, Hiding or showing an item at admin
Controlling user access
*
is pressed again.
mode.
Selcall.
page 478,
level.
477
Need help?