SECTION 4
WORKING ATTACHMENT - GREASING
Before beginning the greasing operation:
- place the working attachment on the ground, com-
pletely extended;
- place the machine in a safe condition.
By means of the greasing pump, grease all lubrica-
tion points of the working attachment.
Release the loading area of the articulation joint.
Remove the protection cap from the grease nipple.
4-20
Clean the grease nipple.
Apply the pump nozzle on the grease nipple.
Now, pump the grease in such a quantity that the
new grease can eject the old one from the articula-
tion points.
Wipe off used grease with a cleaning rag.
After greasing, put protective cap back onto the
grease nipple.