If the tank pump operates correctly can be checked
from outside, by checking the rotation of the mixing
blade (for instance by opening the connection of an
additional lubrication assy or by checking the lamps
of the control board).
PROBLEM
If the pump motor in the tank
does not rotate.
CENTRALIZED LUBRICATION PUMP
POSSIBLE CAUSE
Power supply cut out.
Cut out of electric power supply for
control board.
Cut out of electric power supply from
control board to starter motor.
Control board defective.
Copyright ©
TROUBLESHOOTING
CORRECTION
Check the electric power supply for
the tank pump and, if necessary,
clear the trouble.
Check that the wire from tank pump
connector is linked to the control
board. If power supply is present, the
left lamp is alight.
Start additional lubrication. If power
supply is present, the right lamp (3)
remains alight during the working
time.
Replace control board. Before
assembling the new board, you have
to set the time-outs and working
times as on the old board. Have
these setting performed by the After-
sales service.
2
3
5-19