SECTION 6

BATTERIES STORAGE

For extended machine downtime periods, remove
batteries and store on dry, well ventilated premises
at about 20 °C (68 °F).
Observe the following points:
Clean battery.
Check acid density and battery fluid level once a
fortnight.
Charge batteries when acid density has fallen to
3
3
1.23 kg/dm
(85.71 lb/ft
) or earlier.
Keep batteries clean and dry externally.
6-2
RECOMMISSIONING THE MACHINE
AFTER PROLONGED STORAGE
Before recommissioning the machine after a pro-
longed storage, observe the following points:
Remove engine preservation. Fill in new engine oil.
Install batteries and reconnect them to the electrical
system. Check batteries charge, if necessary
recharge them. Check electrolyte density.
Check the hydraulic oil level in the tank.
Check tyre pressure.
Degrease piston rods of hydraulic cylinders.
Check operation of the electrical system.
Check operation of braking and steering systems.
Check fuel level in the tank and top up if necessary.
Commission engine.
S
DANGER
Do not run the engine in confined spaces without
proper ventilation and/or a suitable system capable
to remove harmful exhaust gases.
Bring machine into driving position and engage the
parking brake.
Bleed air from the hydraulic system.
IMPORTANT: if the machine has not been used for
a long time, oil layers on the sliding surfaces may
have deteriorated.
Operate travel, swing and digging hydraulic sys-
tems 2 or 3 times to lubricate sliding surfaces.