SAFETY INSTRUCTIONS
Place the machine in a safe condition.
The centralized lubrication system, connected to the
pump tank is secured through the pressure limiting
valve (1). The whole system can be checked visu-
ally on the pressure limiting valve. If during the flow
rate the pressure limiting valve is releasing fuel, the
system is somewhere clogged.
Danger of injuries caused by the escape of fuel
under high pressure.
An improper treatment can cause damages due to
the lack or excess of lubrication on bearings and
articulation points.
Modifications or application of the system have to
be carried out only after agreement and Manufac-
turer approval.
OPERATION
OPERATION VISUAL CHECK
The distribution manifolds can be equipped with
checking plug (1). The checking plug is connected
to a little piston inside of the distribution manifold
and during the delivery phase it moves fore and
back. If the system gets clogged, the checking plug
remains stuck.

CENTRALIZED LUBRICATION

Copyright ©
ATTACHMENTS
67