INTRODUCTION
1.4

Basic System Configurations

1.5

Using This Manual

1.6

Conventions Used in This Manual

1−6
EATON Powerware
The following basic UPS system configurations are possible:
S
Single UPS with three common battery UPMs, a common battery FI−UPM, and a
standalone common battery system with a battery disconnect (four UPM
configuration)
S
Single UPS with three common battery UPMs, and a standalone common battery
system with a battery disconnect (three UPM configuration)
S
Single UPS with three separate battery UPMs, a separate battery FI−UPM, and a
standalone separate battery system with a battery disconnect for each UPM (four
UPM configuration)
S
Single UPS with three separate battery UPMs and a standalone separate battery
system with a battery disconnect for each UPM (three UPM configuration)
S
Distributed bypass system with two to five UPSs and a customer−supplied
tie cabinet
The UPS system configuration can be enhanced by adding optional accessories such
as a Remote Emergency Power−off (REPO) control, RMP II, or X−Slot communication
cards.
This manual describes how to install and operate the Powerware 9395
1000–1100 kVA UPS. Read and understand the procedures described in this manual
to ensure trouble−free installation and operation. In particular, be thoroughly familiar
with the REPO procedure (see paragraph 7.3.11 on page 7−18).
The information in this manual is divided into sections and chapters. The system,
options, and accessories being installed dictate which parts of this manual should be
read. At a minimum, Chapters 1 through 4 and Chapter 7 should be examined.
Read through each procedure before beginning the procedure. Perform only those
procedures that apply to the UPS system being installed or operated.
This manual uses these type conventions:
S
Bold type highlights important concepts in discussions, key terms in procedures,
and menu options, or represents a command or option that you type or enter at a
prompt.
S
Italic type highlights notes and new terms where they are defined.
S
Screen type represents information that appears on the screen or LCD.
Icon
Description
Information notes call attention to important features or instructions.
[Keys]
Brackets are used when referring to a specific key, such as [Enter] or [Ctrl].
In this manual, the term UPS refers only to the UPS cabinet and its internal elements.
The term UPS system refers to the entire power protection system – the UPS
cabinet, the battery system, and options or accessories installed.
®
9395 UPS (1000–1100 kVA) Installation and Operation Manual
S
164201764 Rev 1 www.powerware.com