Sign In
Upload
Manuals
Brands
Eaton Manuals
UPS
9395 UPS 10001100 kVA
Eaton 9395 UPS 10001100 kVA Manuals
Manuals and User Guides for Eaton 9395 UPS 10001100 kVA. We have
1
Eaton 9395 UPS 10001100 kVA manual available for free PDF download: Installation And Operation Manual
Eaton 9395 UPS 10001100 kVA Installation And Operation Manual (174 pages)
1000–1100 kVA
Brand:
Eaton
| Category:
UPS
| Size: 2 MB
Table of Contents
Important Safety Instructions
2
Save These Instructions
2
Table of Contents
3
1 Introduction
9
Warranty
9
UPS Standard Features
10
Installation Features
10
Control Panel
10
Figure 1-1. Powerware 9395 Four UPM UPS (1000-1100 Kva)
10
Customer Interface
11
Advanced Battery Management
11
Figure 1-2. Powerware 9395 Three UPM UPS (650-825 Kva)
11
Power Management Software
12
Options and Accessories
12
Field Installed UPM
12
Inherent Redundancy
12
Sync Control
12
Distributed Bypass System
13
Monitoring and Communication
13
Battery System
13
Basic System Configurations
14
Using this Manual
14
Conventions Used in this Manual
14
Symbols, Controls, and Indicators
15
For more Information
15
Getting Help
16
2 Safety Warnings
17
Section I - Installation
19
3 UPS Installation Plan and Unpacking
21
Creating an Installation Plan
21
Preparing the Site
21
Environmental and Installation Considerations
21
Figure 3-1. UPS Cabinet Dimensions (Front View)
23
Figure 3-2. UPS Cabinet Dimensions (Right Side View)
23
Figure 3-3. ISBM Section Dimensions (Front View)
24
Figure 3-4. UPM Section Dimensions (Front View)
24
Figure 3-5. ISBM Section Dimensions (Top View)
25
Figure 3-6. ISBM Section Dimensions (Bottom View)
25
Figure 3-7. UPM Section Dimensions (Top View)
25
Figure 3-8. ISBM Section Center of Gravity
26
Figure 3-9. UPM Section Center of Gravity
26
Figure 3-10. Remote EPO Switch Dimensions
27
UPS System Power Wiring Preparation
28
UPS System Interface Wiring Preparation
39
Distributed Bypass Power Wiring Preparation
40
Inspecting and Unpacking the UPS Cabinets
41
Figure 3-11. UPS Cabinet as Shipped on Pallet (ISBM Section)
42
Figure 3-12. UPS Cabinet as Shipped on Pallet (UPM Section)
43
Unloading the UPS Sections from the Pallet
45
Preliminary Installation Information
45
4 UPS System Installation
45
Figure 4-1. Removing the ISBM Section Left Side Shipping Bracket
46
Figure 4-2. Removing the ISBM Section Right Side Shipping Bracket
47
Figure 4-3. Removing the UPM Section Left Side Shipping Bracket
48
Figure 4-4. Removing the UPM Section Right Side Shipping Bracket
49
Mechanically Joining the Sections
49
Figure 4-5. Section Joining
50
Figure 4-6. ISBM and UPM Sections Joined
51
Electrically Connecting the Sections
52
Figure 4-7. ISBM Section to UPM Section Joining Brackets
52
Figure 4-8. ISBM Section Intercabinet Power Terminal Locations
55
Figure 4-9. ISBM Section Input Power Terminal Detail
56
Figure 4-10. ISBM Section Battery Input Power Terminal Detail
57
Figure 4-11. ISBM Section Output Power Terminal Detail
57
Figure 4-12. UPS Intercabinet Interface Harness Locations
58
Figure 4-13. Pl1 Interface Board Location
59
Figure 4-14. J39 Location on Pl1 Interface Board
59
Battery System Installation
60
Figure 4-17. Distributed Bypass Wire Length
64
Battery Power Wiring
67
TB1, TB2, and TB3 Connections (Other than TB1 Battery Interface Connections)
70
Distributed Bypass Tie Cabinet Installation
60
External Power Wiring Installation
60
Field Installed UPM Installation
60
Installing UPS External and Battery Power Wiring
60
Installing Interface Connections
70
TB1 Battery Interface Connections
75
Figure 4-27. Typical Battery Interface Connection - Common Battery System
76
Figure 4-28. Typical Battery Interface Connection - Separate Battery System
76
X−Slot Connections
77
Installing a REPO Switch
78
Completing the Installation Checklist
81
Initial Startup
81
Installation Checklist
82
Distributed Bypass Installation Checklist
83
Installing Options, Accessories, and Distributed Bypass Control Wiring
81
Installing an Optional Powerware Hot Sync CAN Bridge Card
85
5 Installing Options and Accessories
85
Figure 5-1. Powerware Hot Sync CAN Bridge Card
85
Figure 5-2. Powerware Hot Sync CAN Bridge Card Connections
87
Installing Distributed Bypass Control Wiring
88
Figure 5-3. Distributed Bypass System Can and Pull−Chain Simplified Interface Wiring
89
Figure 5-4. Distributed Bypass System UPS CAN Wiring Without Mobs
89
Figure 5-5. Distributed Bypass Pull−Chain Wiring Without Mobs
90
Figure 5-6. Distributed Bypass Pull−Chain Wiring with Mobs
91
Installing an Optional Remote Monitor Panel II
93
Figure 5-7. Remote Monitor Panel II and Relay Interface Module II Terminal Locations
94
Figure 5-8. Remote Monitor Panel II, Relay Interface Module II, or Supervisory Contact Module II Wiring
94
Installing an Optional Relay Interface Module II
95
Figure 5-9. J1, J2, J3, and J4 15−Pin D−Sub Connectors
96
Figure 5-10. Supervisory Contact Module II Terminal Location
97
Installing an Optional Supervisory Contact Module II
97
Figure 5-11. Supervisory Contact Module II TB2
98
Accessory Mounting Dimensions
99
Figure 5-12. Remote Monitor Panel II Dimensions
99
Figure 5-13. Relay Interface Module II Dimensions
100
Figure 5-14. Supervisory Contact Module II Dimensions
101
Operation
103
6 Understanding UPS Operation
105
UPS System Overview
105
Figure 6-1. Main Elements of the UPS System
105
Normal Mode
106
Single UPS
106
Modes
106
Bypass Mode
107
Figure 6-2. Path of Current through the UPS in Normal Mode
107
Battery Mode
108
Figure 6-3. Path of Current through the UPS in Bypass Mode
108
Figure 6-4. Path of Current through the UPS in Battery Mode
109
Single UPS Unit System Oneline Configurations
110
Figure 6-5. Four UPM UPS System, Dual-Feed, Common Battery System
111
Figure 6-6. Four UPM UPS System, Output Dual-Feed, Separate Battery System
112
Figure 6-7. Three UPM UPS System, Dual-Feed, Common Battery System
113
Figure 6-8. Three UPM UPS System, Dual-Feed, Separate Battery System
114
Figure 6-9. Simplified Dual−Feed UPS with Maintenance Bypass Panel
115
Multiple UPS Distributed Bypass System
116
Multiple UPS Parallel System Modes
116
Figure 6-10. Path of Current through the Upss in Normal Mode – Distributed Bypass
117
Normal Mode – Distributed Bypass
117
Figure 6-11. Path of Current through the Upss in Bypass Mode – Distributed Bypass
118
Bypass Mode – Distributed Bypass
118
Battery Mode – Distributed Bypass
119
Figure 6-12. Path of Current through the Upss in Battery Mode – Distributed Bypass
120
Multiple UPS Distributed Bypass System Oneline Configurations
121
Figure 6-13. Typical Distributed Bypass System (1+1 and 2+0 Configurations)
122
Figure 6-14. Typical Distributed Bypass System (2+1 and 3+0 Configurations)
123
Figure 6-15. Typical Distributed Bypass System (3+1 and 4+0 Configurations)
124
Figure 7-1. UPS Controls and Indicators – ISBM Section Shown
125
7 UPS Operating Instructions
125
UPS Controls and Indicators
125
Control Panel
126
Using the Control Panel
126
Circuit Breaker
126
Figure 7-2. UPS Control Panel
126
Status Indicators
127
System Events
127
Using the LCD and Pushbuttons
128
Figure 7-3. Parts of the LCD
128
Using the Menu
129
MIMIC Screen
129
Figure 7-4. Main Menu and MIMIC Screen (Normal Mode)
129
Display Menu Operation
130
System Status Screen and Controls
132
Figure 7-5. Typical System Status Screen
132
Load off Screen
134
Figure 7-6. Load off Screen
134
Starting the UPS in Normal Mode
135
Single UPS Operation
135
Starting the UPS in Bypass Mode
136
Starting the Upms
136
Transfer from Normal to Bypass Mode
138
Transfer from Bypass to Normal Mode
138
Transfer from Normal to Bypass Mode and Shut down UPS
139
Single UPM Shutdown
139
UPS and Critical Load Shutdown
140
Charger Control
140
Using the UPS LOAD off Pushbutton or Command
141
Using the Remote Emergency Power−Off Switch
142
Figure 7-7. REPO Operation
143
Starting the Distributed Bypass System in Normal Mode
144
Multiple UPS Distributed Bypass Operation
144
Starting the Distributed Bypass System in Bypass Mode
145
Starting the Upss Upms
145
Transfer from Bypass to Normal Mode
147
Transfer from Normal to Bypass Mode
147
Transfer from Normal to Bypass Mode and Shut down All Upss
148
Single UPM Shutdown
148
UPS and Critical Load Shutdown
149
Charger Control
149
Using the UPS LOAD off Pushbutton or Command
150
Using the Remote Emergency Power−Off Switch
151
8 Communication
153
X−Slot Cards
153
Installing Enotify Service
154
Enotify Service Features
154
Enotify Service
154
Figure 8-1. Optional X−Slot Cards
154
Powerware Lansafe Power Management Software
155
Remote Notification
155
Display UPS Control Panel
156
Terminal Mode
156
Event History Log
157
Figure 8-2. Sample Event History Log
158
General Purpose Relay Contact
159
Building Alarm Monitoring
159
Remote Monitor Panel II
159
Figure 8-3. Remote Monitor Panel II Front Panel
159
Relay Interface Module II
161
Figure 8-4. Relay Interface Module II Customer Interface Connectors J1 through J4
161
Supervisory Contact Module II
162
Figure 8-5. Supervisory Contact Module II Enclosure
162
Important Safety Instructions
163
9 UPS Maintenance
163
Performing Preventive Maintenance
164
MONTHLY Maintenance
164
DAILY Maintenance
164
Figure 9-1. ISBM Section Air Filter Locations
165
Figure 9-2. UPM Section Air Filter Locations
166
PERIODIC Maintenance
167
Installing Batteries
167
BATTERY Maintenance
167
ANNUAL Maintenance
167
Figure 9-3. FI−UPM Air Filter Location
167
Recycling the Used Battery or UPS
168
Maintenance Training
168
10 Product Specifications
169
Model Numbers
169
UPS Input
169
UPS Environmental
170
UPS Output
170
Warranty
171
Advertisement
Advertisement
Related Products
Eaton Powerware 5130 Rack/Tower UPS 1250-3000 VA
Eaton 9135 Two-in-One UPS 5000/6000 VA
Eaton 9390 UPS 100160 kVA
Eaton UPS 225275 kVA Powerware 9395
Eaton UPS 20
Eaton 9395 UPS and Plus 1 UPS 650825 kVA
Eaton 9395 Plus 1
Eaton 9395 UPS
Eaton 9395P-600
Eaton 9395P-300
Eaton Categories
UPS
Circuit breakers
Switch
Industrial Equipment
Industrial Electrical
More Eaton Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL