System Status Screen And Controls; Figure 7-5. Typical System Status Screen - Eaton Powerware 9395 UPS 10001100 kVA Installation And Operation Manual

1000–1100 kva
Table of Contents

Advertisement

UPS OPERATING INSTRUCTIONS
Table 7-3. Display Menu Operation (continued)
Function
Subfunction
Com Port Selection
Com Port Setup
Control
UPS
BYPASS
MAINTENANCE BYPASS
CHARGER
UPM: OFFLINE
7−8
EATON Powerware
Operation
The Com Port Setup screen allows selection of the serial COM port to set up. Select COM PORT
SETUP from the System Setup Level 1 menu to display the COM Port Setup screen. Use the up or
down arrow pushbutton to highlight the the COM port to be set up, then press the SELECT
pushbutton
The COM Setup screen is used to change and save the settings for the selected serial
communication port. The COM port number selected from the COM Port Setup screen displays.
If the changes are not wanted, use the ABORT pushbutton to return to the COM Port Setup
screen. Use the up or down arrow pushbutton to highlight the setting to be changed. Use the
return arrow pushbutton to toggle through the values for the setting to make the change. Press
SAVE or ABORT. Once the action is completed, the COM Port Setup screen is displayed.
See paragraph 7.2.7 for details.
7.2.7

System Status Screen and Controls

Press the
CONTROLS
screen. Normal operation, transfer to bypass, charger control, UPM startup and
shutdown and LOAD OFF commands are controlled through this screen. In addition,
the screen displays the current status of the UPS and indicates whether the UPS is in
Maintenance Bypass or Bypass, and the state of the UPM and battery charger.
Figure 7-5 shows the System Status screen.
Use the
or
command screen desired, then press the
command menu screen.
Table 7-4 lists the typical System Status Screen Messages that are displayed during
UPS operation.
Table 7-5 describes the control functions and provides instructions to access and use
the command menu screens.
For detailed information about using the System Controls, see paragraph 7.3.
SYSTEM STATUS

Figure 7-5. Typical System Status Screen

®
9395 UPS (1000–1100 kVA) Installation and Operation Manual
.
To return to the System Setup screen, press the return arrow pushbutton
pushbutton on the main menu bar to display the System Status
pushbutton on the System Status menu bar to highlight the
CONTROLS
:
SHUTDOWN
:
AVAILABLE
:
OFF
:
OFF
CONTROLS
S
164201764 Rev 1 www.powerware.com
.
pushbutton to display the
ESC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerware 9395

Table of Contents