Manuals and User Guides for Eaton 93PM UPS. We have
1
Eaton 93PM UPS manual available for free PDF download: Installation And Operation Manual
Eaton 93PM UPS Installation And Operation Manual (146 pages)
20–50 kW (480V Four Wire) – 50 kW Frame
Brand:
Eaton
| Category:
UPS
| Size: 9 MB
Table of Contents
Table of Contents
5
Introduction
13
UPS Standard Features
13
Installation Features
13
Figure 1-1. Eaton 93PM UPS (20-50 Kw, Four Wire)
14
Figure 1-2. Eaton 93PM UPS (20-50 Kw, Four Wire) with Left or Right Mounted Sidecar
14
Control Panel
15
Customer Interface
15
Energy Saver System Mode
15
Internal Redundancy
15
UL 924 Auxiliary Lighting and Power Equipment Certification
15
Energy Star
15
Advanced Battery Management
16
Options and Accessories
16
Integrated Battery Cabinet
16
Sidecar Integrated Accessory Cabinet-Bypass
17
Top Entry Wiring Sidecar
17
Parallel System
17
Monitoring and Communication
17
Additional Output Surge Protection
18
Battery System
18
Battery Configurations
18
Optional Thermal Sensor
18
Basic System Configurations
19
Using this Manual
19
Conventions Used in this Manual
20
Symbols, Controls, and Indicators
20
For more Information
21
Getting Help
21
Safety Warnings
23
Section 1 - Installation
25
Ups Installation Plan and Unpacking
27
Creating an Installation Plan
27
Preparing the Site
27
Environmental and Installation Considerations
27
Table 3-1. Air Conditioning or Ventilation Requirements During Full Load Operation
28
Table 3-2. UPS Cabinet Weights
29
Table 3-3. UPS Cabinet Clearances
29
Figure 3-1. UPS Cabinet Dimensions (Front and Right Side Views)
30
Figure 3-2. UPS Cabinet Dimensions (Top and Bottom Views)
31
Figure 3-3. UPS Cabinet Front and Back Floor Mounting Bracket Mounting Dimensions (Back Views)
32
Figure 3-4. UPS Cabinet with Left-Mounted or Right-Mounted Sidecar Dimensions (Front and Right Side Views)
33
Figure 3-5. UPS Cabinet with Left-Mounted or Right-Mounted Sidecar Dimensions (Top and Bottom Views)
34
Figure 3-6. UPS Cabinet Center of Gravity
35
Figure 3-7. UPS Cabinet with Left-Mounted or Right-Mounted Sidecar Center of Gravity
36
Figure 3-8. Remote EPO Switch Dimensions
37
UPS System Power Wiring Preparation
38
External Parallel UPS System Power Wiring Preparation
39
Figure 3-9. 93PM External Parallel Wire Length
40
Table 3-4. Input/Output Ratings and External Wiring Requirements for the Eaton 93PM-50-1 and 93PM-50-2 (N+1)
41
Table 3-5. UPS External Power Cable Terminations for the Eaton 93PM-50-1 and 93PM-50-2
42
Table 3-6. Power Cable Conduit Requirements for the Eaton 93PM-50-1 and Eaton 93PM-50-2 (N+1)
43
Table 3-7. Recommended Input and Bypass Circuit Breaker Ratings
44
Table 3-8. Recommended Output Circuit Breaker Ratings
45
Table 3-9. Recommended DC Input Battery Disconnect Circuit Breaker Ratings (240 Cell)
45
UPS System Interface Wiring Preparation
46
Inspecting and Unpacking the UPS Cabinets
47
Figure 3-10. UPS Cabinet as Shipped on Pallet
48
Figure 3-11. UPS Cabinet with Left-Mounted or Right-Mounted Sidecar as Shipped on Pallet
49
Ups System Installation
51
Preliminary Installation Information
51
Unloading the UPS Cabinet from the Pallet
51
Figure 4-1. Removing the Pallet Skids and Supports - Eaton 93PM UPS
52
Figure 4-2. Removing the Sidecar Pallet Skids and Supports - Eaton 93PM UPS
53
Integrated Battery Cabinet Installation
55
Sidecar Integrated Accessory Cabinet-Bypass Wiring Installation
55
Figure 4-3. Removing the Sidecar Rear Shipping Bracket - Eaton 93PM UPS
55
External AC Power Wiring Installation
56
Figure 4-4. UPS Conduit and Wire Entry Locations
57
Figure 4-5. Sidecar Conduit and Wire Entry Locations
58
Figure 4-6. UPS Inter-Cabinet Wiring Access Location
59
Figure 4-7. Power Terminal Locations
60
Battery Power Wiring
61
Figure 4-8. Power Terminal Detail
61
Installing Interface Connections
62
Installing Building Alarm and Relay Contact Connections
62
Figure 4-9. Interface Terminal Locations
63
Figure 4-10. Interface Terminal Detail
64
Figure 4-11. Bottom Access Interface Wiring Locations
64
Figure 4-12. Wire Tie Anchors
65
Figure 4-13. Building Alarm Terminal Block Connector Assignments
65
Table 4-1. Building Alarm Connections and Wire Terminations
65
Installing Battery Detect and Shunt Trip Interface Connections
66
Figure 4-14. Relay Contact Terminal Block Connector Assignments
66
Table 4-2. Relay Contact Connections and Wire Terminations
66
Figure 4-15. Battery Detect and Shunt Trip Terminal Locations
68
Installing Thermal Sensor Interface Connections
69
Figure 4-16. Battery Detect and Shunt Trip Terminal Assignments
69
Figure 4-17. Battery Configuration Jumper Assignments
69
Table 4-3. External Battery Detect and Shunt Trip Connections and Wire Terminations
69
Figure 4-18. Thermal Sensor Terminal Location
71
Figure 4-19. Thermal Sensor Terminal Assignments
72
Figure 4-20. Thermal Sensor Jumper Assignments
72
Table 4-4. Thermal Sensor Connections and Wire Terminations
72
Generator Interface Connections
73
Installing External Parallel CAN Control Wiring and Connections
74
Table 4-5. External Parallel CAN and Pull Chain Connections
75
Table 4-6. External Parallel CAN and Pull Chain Terminal Block Terminations
75
Figure 4-21. External Parallel CAN Wiring
76
Figure 4-22. External Parallel Terminal Block
76
Installing External Parallel Pull Chain Control Wiring and Connections
77
Installing Minislot Interface Connections
78
Figure 4-23. External Parallel Pull Chain Wiring
79
Installing a REPO Switch
80
Figure 4-24. REPO Switch
81
Figure 4-25. REPO Terminal Block Connector Assignments
81
Figure 4-26. Normally-Open REPO Switch Wiring
82
Figure 4-27. Normally-Closed REPO Switch Wiring
82
Table 4-7. Normally-Open REPO Connections and Wire Terminations
82
Table 4-8. Normally-Closed REPO Connections and Wire Terminations
82
Initial Startup
83
Completing the Installation Checklist
83
Section 2 - Operation
87
Understanding Ups Operation
89
UPS System Overview
89
Figure 5-1. Main Elements of the UPS System
89
Single UPS
90
Modes
90
Energy Saver System Mode
90
Energy Saver System Mode
91
Normal Mode
91
Bypass Mode
92
Figure 5-3. Path of Current through the UPS in Normal Mode
92
Battery Mode
93
Figure 5-4. Path of Current through the UPS in Bypass Mode
93
Single UPS Unit System Oneline Configurations
94
Figure 5-5. Path of Current through the UPS in Battery Mode
94
Figure 5-6. Eaton 93PM-50-1 UPS System Oneline with Internal Battery
95
Figure 5-7. Eaton 93PM-50-1 UPS System Oneline with Internal and External Batteries
96
Figure 5-8. Eaton 93PM-50-1 UPS System Oneline with External Battery
97
Figure 5-9. Eaton 93PM-50-2 UPS System Oneline with External Battery
98
Ups Operating Instructions
99
UPS Controls and Indicators
99
Figure 6-1. UPS Controls and Indicators
99
Figure 6-2. UPS Breakers - 93PM-50-1
100
Control Panel
101
Circuit Breakers
101
Figure 6-3. UPS Breakers - 93PM-50-2
101
Using the Control Panel
102
Figure 6-4. UPS Control Panel
102
Status Indicators
103
System Events
103
Table 6-1. Status Indicators
103
Using the LCD Touch Screen
104
Figure 6-5. Parts of the LCD
104
Using the Menu
105
MIMIC Screen
105
Figure 6-6. Main Menu and MIMIC Screen
105
Table 6-2. Display Function Menu Map
105
Display Menu Operation
106
Table 6-3. Display Menu Operation
106
Figure 6-7. Typical Meters Summary Screen
107
Figure 6-8. Typical Active Events Screen
107
Figure 6-9. Typical System Log Screen
108
Figure 6-10. Typical Settings User Screen
108
Figure 6-11. Typical Information Screen
109
Figure 6-12. Typical about Screen
109
Figure 6-13. Typical Settings Configuration 1 Screen
110
Figure 6-14. Typical Settings Configuration 2 Screen
110
Sign in
111
Figure 6-15. Typical Statistics Screen
111
Figure 6-16. Sign in Password Screen
112
Figure 6-17. Sign in Keypad
112
System Controls
113
Figure 6-18. Typical System Control Screen
113
Table 6-4. Controls Menu Operation
113
Table 6-5. Typical System Status Messages
113
Figure 6-19. Typical UPS Control Screen
114
Figure 6-20. Typical UPM Select Screen
114
Figure 6-21. Typical UPM Control Screen
115
Figure 6-22. Typical EAA Control Screen
115
Single UPS Operation
116
Starting the UPS in Double Conversion Mode
116
Starting the UPS in Bypass Mode
117
Starting the Upms
117
Starting a Single UPM
118
Transfer from Double Conversion to Bypass Mode
118
Transfer from Bypass to Double Conversion Mode
119
Transfer from ESS Mode to Double Conversion Mode
119
Transfer from Double Conversion Mode to ESS Mode
119
Transfer from Double Conversion to Bypass Mode and Shut down Upms
119
6.3.10 Single UPM Shutdown
120
6.3.11 Single UPM Restart
120
Figure 6-23. REPO Operation
123
Figure 7-1. Optional Minislot Cards
133
Table 7-1. IRC-MS Default Triggers
133
Figure 8-1. Air Filter Location
139
Advertisement
Advertisement
Related Products
Eaton 93PM-L IAC-B
Eaton 93PM-150(400)
Eaton 93PM-200(400)
Eaton 93PM 50 kW SIAC-B Three-Wire
Eaton 93PM-100-1
Eaton 93PM-50-2
Eaton 93PM G2 300(300)
Eaton 93PM Gen 2 150-1
Eaton 93PM-150-1
Eaton 93PM-150-2
Eaton Categories
UPS
Circuit breakers
Switch
Industrial Equipment
Industrial Electrical
More Eaton Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL