Selection Of Molded-Case Circuit Breaker, Fuse, And Magnetic Contactor (Example); Mr-J3 Series, Molded-Case Circuit Breakers, Fuses, And Magnetic Contactors - Mitsubishi Electric MELSERVO-J3 Series Handbook

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 8: Review on Replacement of Optional Peripheral Equipment

4.3 Selection of Molded-Case Circuit Breaker, Fuse, and Magnetic Contactor (Example)

4.3.1 MR-J3 series, molded-case circuit breakers, fuses, and magnetic contactors

CAUTION
When using a fuse instead of the molded-case circuit breaker, use the one having the specifications given in
this section.
Servo amplifier
MR-J3-10_(1)
MR-J3-20_
MR-J3-20_1
MR-J3-40_
MR-J3-60_/70_/100_/40_1
MR-J3-200_
MR-J3-350_
MR-J3-500_
MR-J3-700_
MR-J3-11K_
MR-J3-15K_
MR-J3-22K_
MR-J3-60_4
MR-J3-100_4
MR-J3-200_4
MR-J3-350_4
MR-J3-500_4
MR-J3-700_4
MR-J3-11K_4
MR-J3-15K_4
MR-J3-22K_4
Note 1. When not using the servo amplifier as a UL/CSA Standard compliant product, K5 class fuse can be used.
2. Be sure to use a magnetic contactor with an operation delay time of 80ms or less.
3. Use a molded-case circuit breaker which has the same or more operation characteristics than our lineup.
Select a molded-case circuit breaker with a short shut-off time to prevent smoking
and fire from the servo amplifier.
Always use one molded-case circuit breaker and one magnetic contactor with one
servo amplifier.
Molded-case circuit breakers, fuses, and magnetic contactors
Molded-case circuit breaker (Note 3)
Current
Not using power factor
Using power factor
improving reactor
improving reactor
30 A frame 5 A
30 A frame 5 A
30 A frame 10 A
30 A frame 10 A
30 A frame 10 A
30 A frame 15 A
30 A frame 10 A
30 A frame 20 A
30 A frame 15 A
30 A frame 30 A
30 A frame 30 A
50 A frame 50 A
50 A frame 40 A
100 A frame 75 A
50 A frame 50 A
100 A frame 100 A
100 A frame 75 A
225 A frame 125 A
100 A frame 100 A
225 A frame 175 A
225 A frame 150 A
30 A frame 5 A
30 A frame 10 A
30 A frame 10 A
30 A frame 15 A
30 A frame 15 A
30 A frame 20 A
30 A frame 20 A
30 A frame 30 A
30 A frame 30 A
50 A frame 40 A
50 A frame 30 A
60 A frame 60 A
50 A frame 50 A
100 A frame 75 A
60 A frame 60 A
225 A frame 125 A
100 A frame 100 A
Voltage
AC
30 A frame 5 A
30 A frame 5 A
30 A frame 5 A
240 V
30 A frame 5 A
600 Y/347 V
8 - 27
Fuse
Class
Voltage
Current
(Note 1)
AC
10 A
10 A
15 A
15 A
20 A
40 A
300 V
70 A
125 A
150 A
200 A
T
250 A
350 A
10 A
15 A
25 A
35 A
50 A
600 V
65 A
100 A
150 A
175 A
Magnetic
contactor
(Note 2)
S-N10
S-N18
S-N20
S-N35
S-N50
S-N65
S-N95
S-N125
S-N10
S-N18
S-N20
S-N25
S-N35
S-N65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents