4.6 LPG
CONFIGURATION
4.6.1

Preparations

4-20
Before starting configuration of the Rosemount 5900S for LPG
measurements, ensure that all mechanical installations are made according
to instructions, and all external sensors such as pressure and temperature
sensors are properly connected.
Make sure that the position of the Verification Pin is accurately measured and
the inner diameter of the still-pipe is available.
Install the tank and the Rosemount 5900S level gauge in TankMaster
WinSetup as described in the Raptor System Configuration Manual
(Document no. 300510EN). Ensure that the appropriate tank and device
types are selected, and the temperature and pressure sensors are properly
configured. Check that the gauge communicates with the TankMaster PC.
For 5900S with F
OUNDATION
Setup Using DeltaV / AMS Device Manager" on page 4-77.
Highly pressurized vapor above the product surface affects the propagation
speed of microwaves. The Rosemount 5900S level gauge is able to
compensate for this, thus avoiding deviations in measured level due to the
vapor.
When the gauge is installed on the empty tank, calibrate the gauge and
configure for LPG measurements.
To install a Rosemount 5900S for LPG measurements perform the following
major steps:
a. Install the 5900S gauge on the still-pipe. Measure the exact distance
to the Verification Pin.
b. Use TankMaster Winsetup to configure the 5900S according to the
standard procedure for installation of a Rosemount 5900S level
gauge (see the Raptor System Configuration Manual (Document no.
300510EN).
c. Configure the vapor pressure sensor.
d. Calibrate the 5900S.
e. Configure the Verification Pin.
f. Confirm position of Verification Pin.
g. Set up the Correction Method that applies to the particular type of
product in the tank.
The LPG installation procedure using TankMaster Winsetup is described in
section "LPG Setup Using TankMaster" on page 4-21.