Other Memory error
Microwave Module error
RM error
Other hardware error
Configuration error
Software error
6-22
Message
Input register no. 6006.
Input register no. 6008.
Bit 0: Not connected
Input register no. 6010
Bit 1: SW configuration
Bit 5: FPROM Checksum
Bit 6: FPROM Version
Bit 9: HREG Checksum
Bit 10: HREG Limit
Bit 11: HREG Write
Bit 12: HREG Read
Bit 13: HREG Version
Bit 14: MWM Invalid Id
Bit 30: SW Serious Error
Input register no. 6022.
An unspecified hardware error has
been detected.
Bit 0: Internal Temp Out of Range
Input register no. 6028.
At least one configuration parameter
is outside allowed range.
NOTE: the default values are used
until the problem is solved.
Bit 0: Start Code
Bit 1: FF Unit Conversion
Input register no. 6030.
An error has been detected in the
5900S gauge software.
Bit 0: DSP Undefined SW Error
Bit 1: DSP Task Not Running
Bit 3: Simulated error
Description
Contact Emerson Process
Management/Rosemount TankGauging
service department.
• Load the default database and restart the
• Configure the level gauge or load a backup
• Contact Rosemount TankGauging service
Contact Emerson Process
Management/Rosemount TankGauging
service department
Section 6. Service and Troubleshooting
Reference Manual
00809-0100-5900, Rev CA
Action
level gauge, see "Loading the Default
Database" on page 6-14.
configuration file (see "To Recover a
Backup Configuration Database" on
page 6-6).
department if the problem persists.