Section 4. Configuration
11. Choose one of the predefined Antenna Types to match the antenna
attached to the 5900S Radar Level Gauge.
For Still-pipe Array antennas the antenna size is also required. Sizes
ranging from 5 to 12 inch are available.
Enter the Pipe Diameter if the 5900S is installed in a Still-pipe.
12. Click the Next button to open the Measurement Setup - Geometry
window.
F
Fieldbus parameters:
OUNDATION
TRANSDUCER 1100>ANTENNA_TYPE
TRANSDUCER 1100>ANTENNA_SIZE
TRANSDUCER 1100>PIPE_DIAMETER
TRANSDUCER 1100>HOLD_OFF_DIST