Rosemount 5900S Series
5900S with horn antenna
Operating temperature in tank
Measuring range
Pressure range
Material exposed to tank atmosphere
Antenna dimension
Nozzle diameter
Tank connection
5900S with still-pipe array antenna
Operating temperature in tank
Measuring range
Pressure range
Material exposed to tank atmosphere
Still-pipe dimensions
Tank connection
5900S with LPG/LNG antenna
Operating temperature at ball valve
Operating temperature in tank
Measuring range
Pressure range
Pressure sensor (option)
Material exposed to tank atmosphere
Still-pipe dimension compatibility
Flange size & rating
(1) Instrument accuracy is under reference conditions. Reference conditions are: Measurement in test bench at Rosemount Tank Radar AB in Göteborg
Sweden. Test bench is calibrated minimum yearly by an accredited laboratory (SP Technical Research Institute of Sweden. Measuring range is up to
30 m (98 ft). Ambient temperature and humidity is close to constant during tests. Total uncertainty in test bench is below 0.15 mm (0.006 in.).
(2) Some degradation of accuracy may be expected on the secondary unit.
A-4
Max. +230 °C (+445 °F)
0.8 to 20 m (2.6 to 65 ft) below flange
Possibility to measure 0.5 to 30 m (1.6 to 100 ft). Accuracy may be reduced
-0.2 to 2 bar (-2.9 to 29 psig)
Antenna and flange: material corresponds to AISI 316/316L and EN 1.4401 /1.4404
Sealing: PTFE
O-ring: Viton fluoroelastomer
175 mm (7 in.)
Minimum 200 mm (8 in.)
8 in. hole pattern according to ANSI 8 in. Class 150 / DN 200 PN 10.
The flange can be horizontal or 4° inclined for installation close to the tank wall.
Other flanges are available on request
-40 to 120 °C (-40 to 248 °F)
0.8 to 30 m (2.6 to 100 ft)
below flange
Possibility to measure 0.5 to 40 m (1.6 to130 ft). Accuracy may be reduced
For longer measuring range, please consult your Rosemount Tank Gauging
representative
Fixed version: -0.2 to 2 bar (-2.9 to 29 psig) at 20 °C
Hinged hatch version: -0.2 to 0.5 bar (-2.9 to 7.2 psig) for 5 to 8-in. pipes
-0.2 to 0.25 bar (-2.9 to 3.6 psig) for 10 and 12-in. pipes
Antenna: Polyphenylenesulphide (PPS)
Sealing: PTFE
O-ring: Fluorosilicone
Flange: material corresponds to AISI 316/316L and EN 1.4401 /1.4404
5-, 6-, 8-, 10- or 12 in.
8 in. hole pattern according to ANSI 8 in. Class 150 / DN 200 PN 10
-55 to 90 °C (-67 to 194 °F)
-170 to 90 °C (-274 to 194 °F)
1.2 m to 30 m
(3.9 to 100
ft) below flange
Possibility to measure 0.8 to 60 m (2.6 to 200 ft). Accuracy may be reduced
For longer measuring range, please consult your
representative
-1 to 25 bar (-14.5 to 365 psig).
Note! Flanges may have higher pressure rating than 25 bar, but maximum tank pressure
is still 25 bar
Rosemount 2051. It is available with different hazardous location certifications.
For more information see the 2051 Product Data Sheet (document number
00813-0100-4101)
Antenna and flange: material corresponds to AISI 316/316L and EN 1.4401 /1.4404
Sealing: Quartz and PTFE
Antenna choices for 4-in. sch. 10, 4-in. sch 40, or 100 mm (99 mm inner diameter)
still-pipe dimensions
4 in.
class 150/300
6 in.
class 150/300
8 in.
class 150/300
Reference Manual
00809-0100-5900, Rev CA
June 2014
Rosemount Tank Gauging
Appendix A. Reference Data