Figure 3-6. Nozzle requirements
for the Rosemount 5900S with
Parabolic Antenna
Minimum 800 mm for
highest accuracy
Minimum 500 mm with
reduced accuracy
3-8
Nozzle Requirements
When installing the 5900S with Parabolic Antenna on a Ø 20" nozzle, the
nozzle height must not exceed 600 mm. There has to be a free passage for
the radar beam within a 5° angle from the edge of the parabolic reflector to
the lower end of the nozzle.
The 5900S should be installed so that the distance between flange and
product surface exceeds 800 mm. Highest accuracy is obtained for product
levels below this point.
Ø > 500 mm (20 inch)
5° minimum
Vertical plumb line
Nozzles with larger diameter may be higher than 0.6 meter as long as the
requirement of 5° free passage is fulfilled.
5° minimum
Ø 440 mm
Reference Manual
00809-0100-5900, Rev CA
June 2014
Recommended height: 400 mm
Maximum height: 600 mm