Rosemount 5900S Series
B.3.2
Factory Mutual
Canadian Approvals
Figure B-2. Factory Mutual
Intrinsic Safety Canadian
Approval Label
B-4
Certificate of Compliance: 3035466C.
I6
FISCO Field Device
Intrinsically Safe for Class I, II, III, Division 1, Groups A, B, C, D, E, F, and G
Ex ia IIC
For each channel: Ui=17.5 V, Ii=380 mA, Pi=5.32 W, Ci=1.1 nF, Li=1.5 μH
Entity
Intrinsically Safe for Class I, II, III, Division 1, Groups A, B, C, D, E, F, and G
Ex ia IIC
For each channel: Ui=30 V, Ii=300 mA, Pi=1.3 W, Ci=1.1 nF, Li=1.5 μH
Dust Ignition Proof for Class II/III, Division 1, Groups E, F and G
Temperature Code T4
Install per Control Drawing 9240040-917
Ambient Temperature Limits: -50 °C to +80 °C
Special Conditions of Use
1. Parabolic and Array antennas with plastic surfaces and the surface of the
painted housing may, under certain extreme conditions, generate an
ignition-capable level of electrostatic. Appropriate measures must be
taken to prevent electrostatic discharge.