Antenna
Waveguide
Section 3. Installation
Nut
Finger Nut
Tank
Tank center
45°
Line of sight
Rosemount 5900S Series
10. Put the level gauge on the Antenna
Waveguide. Ensure that the guide
pin inside the transmitter head fits
into the groove on the Antenna
Waveguide.
11. Tighten the nut that connects the
transmitter head to the antenna.
12. Loosen the finger nut slightly.
13. The lid on top of the transmitter head
has cross hairs that can be used to
properly align the transmitter. In case
the weather protection hood is
attached, the 5900S can be aligned
by using a line of sight along the
screws on top of the transmitter
head.
14. Ensure that the gauge is directed at
an angle of 45° to the line of sight
from the center of the tank to the
wall.