Spare Parts - Emerson Rosemount 5900S Series Reference Manual

Radar level gauge
Hide thumbs Also See for Rosemount 5900S Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-5900, Rev CA
June 2014
www.rosemount-tg.com
Rosemount 5900S
Radar Level Gauge
Read this manual before working with the product. For personal and system safety, and for
optimum product performance, make sure you thoroughly understand the contents before
installing, using, or maintaining this product.
For equipment service or support needs, contact your local Emerson Process
Management/Rosemount Tank Gauging representative.

Spare Parts

Any substitution of non-recognized spare parts may jeopardize safety. Repair, e.g.
substitution of components etc, may also jeopardize safety and is under no circumstances
allowed.
Rosemount Tank Radar AB will not take any responsibility for faults, accidents, etc caused
by non-recognized spare parts or any repair which is not made by
Rosemount Tank Radar AB.
Specific ETSI Requirements (Europe)
The Rosemount 5900S is required to be installed at a permanent fixed position at a closed
(not open) metallic tank or reinforced concrete tank, or similar enclosure structure made of
comparable attenuating material. Flanges and attachments of the Rosemount 5900S
equipment shall provide the necessary microwave sealing by design.
Manholes or connection flanges at the tank shall be closed to ensure a low-level leakage of
the signal into the air outside the tank.
Installation and maintenance of the Rosemount 5900S equipment shall be performed by
professionally trained individuals only.
Specific FCC Requirements (USA)
Rosemount 5900S generates and uses radio frequency energy. If it is not installed and used
properly, that is, in strict accordance with the manufacturer´s instructions, it may violate
FCC regulations on radio frequency emission.
Rosemount TankRadar 5900S has been FCC certified under test conditions which assume
a metallic tank.
Specific IC Requirements (Canada)
Radio approvals for this device apply for installation in complete enclosed container to
prevent unwanted RF emission. In open air application site license is required. Installation
shall be done by trained installers, in compliance with the manufacturer's instructions.
The use of this device is on a "no-interference, no-protection" basis. That is, the user shall
accept operations of high-powered radar in the same frequency band which may interfere
with or damage this device. Devices found to interfere with primary licensing operations will
be required to be removed at the user's expense.
Low Emission of Microwave Radiation
The microwave radiation emitted by a Rosemount 5900S radar level gauge is very low
compared to limits given by the Rec. 1999/519/EC (much less than 0.1 mW). No additional
safety measures are needed.