5900S Radar Level Gauge Options - Emerson Rosemount 5900S Series Reference Manual

Radar level gauge
Hide thumbs Also See for Rosemount 5900S Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-5900, Rev CA
June 2014
Code (Pos 11) Antenna
G1
LNG still-pipe antenna
G2
LPG still-pipe antenna
Code (Pos 12) Antenna Size
A
4 in. Schedule 10, Ø=107 mm (4.2 in.)
B
4 in. Schedule 40, Ø=101 mm (4.0 in.)
D
DN 100, Ø=99 mm (3.9 in.)
Code (Pos 13) Antenna Material
S
Stainless steel (material type corresponding to AISI 316/316L and EN 1.4401 /1.4404)
Code (Pos 14) Tank Seal
QA
Quartz sealing
Code (Pos 15) Tank Connection
ANSI Flanges (SST AISI 316L)
4A
4 in. Class 150
4B
4 in. Class 300
6A
6 in. Class 150
6B
6 in. Class 300
8A
8 in. Class 150
8B
8 in. Class 300
Code (Pos 16) Special
V
Measurement verification kit
0
None
A.3.3

5900S Radar Level Gauge Options

Code
Options – none or multiple selections are possible. Specify in the
same order as below
QT
IEC 61508 certificate and FMEDA-data
Q4
Calibration certificate
S4
Witnessed calibration certificate
Q8
Antenna material traceability certification per EN 10204 3.1
ST
Engraved SST tag plate
P1
Antenna hydrostatic pressure testing
(3)
U1
TÜV/DIBt WHG Approval for Overfill protection
(1) Requires Pos 3 "Safety Certification (SIS)" code 2 or 3 (SIL 3 or SIL 2).
(2) Certificate includes all pressure retaining wetted parts.
(3) Requires one or more relay outputs in the Rosemount 2410 Tank Hub
Appendix A. Reference Data
LPG/LNG Antenna
(1)
Model code example, Rosemount 5900S with still-pipe array antenna
5900S - P 3 2 F I1 R 1 A 1 - 1A 8 S HH 8A 0 - QT Q4
Rosemount 5900S Series
Note
Including integrated ball valve
Including integrated ball valve and pressure
transmitter
Note
Note
Note
Note
Note
Includes one verification pin and a pipe-end
deflector kit
Note
Calibration certificate witnessed by factory
selected third part metrology certified institute