Emerson Rosemount 5900S Series Reference Manual page 177

Radar level gauge
Hide thumbs Also See for Rosemount 5900S Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-5900, Rev CA
June 2014
Section 6. Service and Troubleshooting
Multiple devices
To save a backup copy of the current configuration for multiple devices, do
the following:
1. Start the TankMaster WinSetup program.
2. In the TankMaster WinSetup workspace window select the Devices
folder.
3. Click the right mouse button and choose the Devices/Save Database of
All to Files option.
This option is also available from the Service/Devices menu.
4. Select a device from the Available Devices pane and click the Add
button in order to move it to the Selected Devices pane. Repeat for all
devices you wish to include.
5. Choose the Holding Registers and Predefined Registers options (the
User-Defined option should only be used for advanced service).
6. Click the Browse button, select a folder and type a name for the backup
file.
7. Click the Start button to save the database backup.
The backup file can be viewed as a text file in a word processing program