A.1 SPECIFICATIONS
General
Product
Measurement principle
Antennas
(1)
Instrument accuracy
Temperature stability
Fieldbus (standard)
Update time
Repeatability
Maximum level rate
Metrology sealing possibility
Legal custody transfer type approval
Hazardous location certifications
Safety/overfill
CE-mark
Ordinary location certification
SIL Certification
OIML R85:2008 accuracy certification
National metrological approvals
German WHG certification
Communication / Display / Configuration
Output variables and units
Configuration tools
www.rosemount-tg.com

Reference Data

A.1
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1
A.2
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . page A-5
A.3
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . page A-9
Rosemount 5900S Radar Level Gauge
FMCW (Frequency Modulated Continuous Wave)
Horn antenna, parabolic antenna, still-pipe array antenna, LPG/LNG antenna
± 0.5 mm (0.020 in.)
Typically < ± 0.5 mm (0.020 in.) in -40 to +70 °C (-40 to +158 °F)
F
™ fieldbus FISCO (Tankbus)
OUNDATION
New measurement every 0.3 s
0.2 mm (0.008 in.)
Up to 200 mm/s
Yes
OIML R85:2008, and national certifications such as PTB, NMi etc
ATEX, FM-C, FM-US, IECEx, and national certifications. For details see Appendix B:
Product Certifications.
SIL 2 and SIL 3 certified. TÜV tested and WHG approved for overfill prevention. For
national approvals, consult your local Rosemount Tank Gauging representative
93/68/EEC: complies with applicable EU directives (EMC, ATEX, LVD, and R&TTE).
Based on the low emitted effects from the gauges (below 0.1 mW) compared to limits
given by the Rec. 1999/519/EC, no additional measures are needed
Complies with FM 3810:2005 and CSA: C22.2 No. 1010.1
The SIL safety certificate, issued by exida, includes the SIL alarm channel within the
5900S Radar Level Gauge and the 2410 Tank Hub. Both units are SIL 2 and SIL 3
capable according to IEC 61508, parts 1-7.
Certificate number is Rosemount 091243 P0017 C001.
The OIML metrology certificate, issued by the SP Technical Research Institute of
Sweden, covers the Rosemount Tank Gauging system, including the level gauges
equipped with different antennas.
Certificate number is R85/2008-SE-11.01.
Other national legal custody transfer certifications like PTB, MNi
etc are available (see "Ordering Information" on page A-9)
The certificate for the 5900S radar level gauge and the 2410 Tank Hub is issued by DIBt
(Deutsches Institut für Bautechnik) according to the German WHG regulations for
overfill prevention. It is based on technical evaluation and testing conducted by TÜV
NORD CERT GmbH.
Certificate number is Z-65.16-500.
Level, and ullage: meter, centimeter, millimeter, feet, or inch
Level rate: meter/second, meter/hour, feet/second, feet/hour, inch/minute
Signal strength: mV
Rosemount TankMaster WinSetup, Field Communicator