Rosemount 5900S Series
4-30
Procedure
Follow these instructions when you make hand dip measurements:
hand dip until three consecutive readings within 1 mm are obtained
correct the tape according to the calibration record
note the hand dipped ullage and the gauge level reading
simultaneously
Do not calibrate when
the tank is being emptied or filled
agitators are running
when there are windy conditions
when there is foam on the product surface