Environment
Ambient operating temperature
Storage temperature
Humidity
Ingress protection
Vibration resistance
Telecommunication
Electromagnetic compatibility
Transient / built-in lightning protection
Pressure Equipment Directive (PED)
Low Voltage Directive (LVD)
5900S standard version
Built-in Tankbus terminator
Daisy chain possibility
5900S 2-in-1 version
(1)
Instrument accuracy
Separation
Wiring
Tank hub connection
Built-in Tankbus terminator
Daisy chain possibility
5900S SIL version
Separation
Built-in Tankbus terminator
Daisy chain possibility
Electric properties for intrinsically safe alarm
signal
Wiring
5900S with parabolic antenna
Operating temperature in tank
Measuring range
Pressure range
Material exposed to tank atmosphere
Antenna dimension
Manway size
Tank connection
Appendix A. Reference Data
-40 to +70 °C (-40 to +158 °F). Minimum start-up temperature is -50 °C (-58 °F)
-50 to +85 °C (-58 to +185 °F)
0-100% relative humidity
IP 66/67 and Nema 4X
IEC 60770-1 level 1 and IACS UR E10 test 7
Compliance with:
• FCC 15B Class A, and 15C
• R&TTE (EU directive 99/5/EC) ETSI EN 302372; EN 50371
• IC (RSS210-5)
• EMC (EU directive 2004/108/EC) EN 61326-1; EN 61326-3-1
• OIML R85:2008
According to IEC 61000-4-5, level 2 kV line to ground. Complies with IEEE 587
Category B transient protection and IEEE 472 surge protection
97/23/EC
LVD (EU directive 2006/95/EC) EN/IEC 61010-1
Yes (to be connected if required)
Yes
(2)
± 0.5 mm (0.020 in.)
Galvanically separated gauge electronics, and shared antenna for the two units
Separated or common
• Connection of both units to one hub, or
• Separate connection of units to two different hubs
Single Tankbus connection: Yes (to be connected if required)
Dual Tankbus connection: Possible to terminate the primary Tankbus
No
Galvanically separated gauge electronics, and shared antenna for the SIL 3 version
No
No
12.5 VDC, 1-2 mA for normal condition (no alarm)
• Additional separate 2-wire cable for alarm or
• A single cable incorporating two 2-wire cables (alarm and level)
For cable specification, see page A-2
Max. +230 °C (+445 °F)
0.8 to 30 m (2.6 to 100 ft) below flange
Possibility to measure 0.5 to 50 m (1.6 to 164 ft). Accuracy may be reduced
For longer measuring range, please consult your
representative
Clamped/threaded: -0.2 to 0.2 bar (-2.9 to 2.9 psig)
Welded: -0.2 to 10 bar (-2.9 to 145 psig)
Antenna: material corresponds to AISI 316/316L and EN 1.4401 /1.4404
Sealing: PTFE
O-ring: FEP fluoropolymer
440 mm (17 in.)
500 mm (20-in.) opening
The gauge is clamped in a 96 mm (3.78 in.) diameter hole, or welded in a 117 mm
(4.61 in.) diameter hole
Rosemount 5900S Series
Rosemount Tank Gauging
A-3