Turning On and Shutting Down the System
1. Scale variant only:
a) Switch on both PSU switches on the rear side of each storage base and expansion
b) Check that the LINE LEDs of all storage expansion modules are green.
c) At the storage base module, press the power ON/OFF button which is located at the
d) Wait until the READY LED of the storage base module glows green.
2. At the server module, press the power ON/OFF button which is located at the front
panel on the right side.
The server is switched on, performs a system test and boots the operating system.
3. Wait about 15 minutes before starting any further actions (such as configurations via
software).
Shutting Down the System
To shut down the ETERNUS CS800 S5, use the remote management pages (see
& Shutdown" on page
server is switched off and goes into standby mode. The power-on indicator lights up orange.
I
The storage modules are not switched off by shutting down the ETERNUS CS800 S5 via
the remote management pages. If you want to switch off the storage modules completely,
wait until the server has shut down, then press the Power ON/OFF button of the storage
base module(s) for several seconds until the READY LED does not glow any more. This
can take about 10 seconds.
76
module.
front panel on the left side.
447). Shutting down the system can take up to 15 minutes. The
If the operating system does not switch the server off automatically, press the
ON/OFF button for at least 10 seconds and/or send a corresponding control signal.
Hardware Description and Basic Operations
"Reboot
U41840-J-Z125-7-76