Fujitsu ETERNUS CS800 S5 User Manual page 52

File
Table of Contents

Advertisement

Server
Item
8
9
10
11
12
13
14
15
50
Indicator, Button, Port
CSS indicator
(yellow)
Temperature error indicator
(orange)
Fan error indicator
(orange)
Global Error indicator
(orange)
Memory error indicator
(orange)
PSU error indicator
(orange)
CPU error indicator
(orange)
HDD/SSD error indicator
(orange)
Hardware Description and Basic Operations
Description
Lights up yellow if a prefailure event was
detected for a CSS (Customer Self Service)
component that you can fix yourself (for reasons
of precaution) with the CSS concept. Flashes
yellow if an error was detected that you can fix
yourself with the CSS concept. Does not light up
when the system is OK. If the event is still acute
after a power failure, the indicator is activated
after the restart. The indicator also lights up in
standby mode.
Operating temperature levels above permitted
limits.
Fan prefailure or failure event detected.
Lights up orange if a prefailure event has been
detected that requires (precautionary) service
intervention. Flashes orange if an error was
detected that requires service intervention. Does
not light up if there is no critical event. If the event
is still acute after a power failure, the indicator is
activated after the restart. The indicator also
lights up in standby mode.
Memory module failure detected.
Hot-plug PSU module failure detected.
I
Only available in redundant PSU
configurations.
CPU prefailure event detected.
HDD / SSD, SAS / SATA backplane or RAID
controller failure detected.
U41840-J-Z125-7-76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents