Fujitsu PRIMERGY CX400 M6 Upgrade And Maintenance Manual

Fujitsu PRIMERGY CX400 M6 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Quick Links

Upgrade and Maintenance Manual - English
FUJITSU Server PRIMERGY CX400 M6
Server Enclosure
Upgrade and Maintenance Manual
06/2021

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu PRIMERGY CX400 M6

  • Page 1 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY CX400 M6 Server Enclosure Upgrade and Maintenance Manual 06/2021...
  • Page 2 All hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from – the use of any information in this manual.
  • Page 3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure that these safety notes are understood before using the product.
  • Page 4 Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning.
  • Page 5 HDD, see the following internet address: https://jp.fujitsu.com/platform/server/primergy/harddisk/ Only for Japan: Shielded LAN cables should be used in this product. UK Importer information Fujitsu Services Limited 22 Baker Street, London, W1U 3BW, United Kingdom CX400 M6 Upgrade and Maintenance Manual...
  • Page 6 Version history Issue Issue date Description number V 1.0 11/2020 Early release V 2.0 06/2021 General release Upgrade and Maintenance Manual CX400 M6...
  • Page 7: Table Of Contents

    Content Introduction Concept and target groups of this manual Notational conventions Before you start Basic information 2.1.1 Proceeding 2.1.2 Advanced Thermal Design (ATD) 2.1.3 Installing optional components Classification of procedures 2.2.1 Assignment of unit categories 2.2.2 Customer Replaceable Units (CRU) 2.2.3 Upgrade and Repair Units (URU) 2.2.4...
  • Page 8 Content 3.2.3 Installation and operation 3.2.4 Batteries 3.2.5 Working with optical disk drives (ODDs) and media 3.2.6 Laser information 3.2.7 Modules with Electrostatic-Sensitive Devices (ESD modules) 3.2.8 Transporting the server enclosure 3.2.9 Installing the server enclosure in the rack 3.2.10 Other important information ENERGY STAR CE conformity...
  • Page 9 Content Reassembling 4.8.1 Installing the top covers 4.8.2 Installing the rack rails 4.8.3 Installing the server enclosure in the rack 4.8.4 Sliding the server enclosure into the rack 4.8.5 Installing the cable management arm (CMA) Installing the server node dummy module 4.10 Installing server nodes in the server enclosure 4.11...
  • Page 10 Content Hard disk drive (HDD) / solid state disk (SSD) Safety notes Basic information Installing 2.5-inch HDD/SSD modules Removing 2.5-inch HDD/SSD modules Replacing a 2.5-inch HDD/SSD module Replacing a 2.5-inch HDD/SSD backplane Installing or removing the HDD/SSD bridge board Replacing the HDD/SSD bridge board Changing HDD/SSD cage bezels Fans Safety notes...
  • Page 11 Content 10.2 Basic information 10.3 Removing the power distribution board kit 10.4 Installing the power distribution board kit 10.5 Replacing the power distribution board Front panel 11.1 Safety notes 11.2 Front panel module 11.2.1 Replacing the left front panel module 11.2.2 Replacing the right front panel module 11.3...
  • Page 12 Content 13.2 Connectors and indicators 13.2.1 Server enclosure front 13.2.1.1 Indicators on the front panel 13.2.1.2 Indicators on hot-plug HDD / SSD / PCIe SSD modules 13.2.2 Server enclosure rear 13.2.2.1 Indicator on hot-plug PSU 13.2.2.2 Fan indicators 13.2.2.3 Indicators of the server nodes 13.3 Minimum startup configuration Appendix B...
  • Page 13: Introduction

    Introduction Concept and target groups of this manual This upgrade and maintenance manual provides instructions for the following procedures: – Upgrading the server configuration by adding optional hardware components. – Upgrading the server configuration by replacing existing hardware components with superior ones. –...
  • Page 14 Introduction "Quotation marks" Indicate names of chapters and terms that are being emphasized. ▶ Describes activities that must be performed in the order shown. [Abc] Indicates keys on the keyboard. Pay particular attention to texts marked with this CAUTION symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.
  • Page 15: Before You Start

    Before you start Basic information 2.1.1 Proceeding Before you start any upgrade or maintenance task, proceed as follows: ▶ Carefully read the safety instructions, see "Important information" on page ▶ Make sure that all necessary manuals are available, see "Documentation overview"...
  • Page 16: Installing Optional Components

    For Japan: https://www.fujitsu.com/jp/products/computing/servers/primergy/ Please contact your local Fujitsu customer service partner for details on how to order expansion kits or spare parts. Classification of procedures 2.2.1 Assignment of unit categories The complexity of maintenance procedures varies significantly.
  • Page 17: Customer Replaceable Units (Cru)

    Before you start Please ask your local Fujitsu service center for more information. 2.2.2 Customer Replaceable Units (CRU) Customer Replaceable Units (CRU) Customer Replaceable Units are intended for customer self service and may be installed or replaced as hot-plug components during operation.
  • Page 18: Field Replaceable Units (Fru)

    CAUTION Installing procedures involving Upgrade and Repair Units must be performed exclusively by Fujitsu service personnel or technicians trained by Fujitsu. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.
  • Page 19: Average Task Duration

    CAUTION Maintenance procedures involving Field Replaceable Units must be performed exclusively by Fujitsu service personnel or technicians trained by Fujitsu. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Components that are handled as Field Replaceable Units –...
  • Page 20: Tools You Need At Hand

    Before you start Step included Explanation Shutdown time depends on hardware and software configuration and may vary significantly. Server shutdown Software tasks necessary before maintenance, see "Starting the maintenance task" on page Rack removal, Making the server available, removing the disassembly server from the rack (if applicable).
  • Page 21: Documentation Overview

    Important safety information, available online, Regulations" manual or as a printed copy "安全上のご注意" for Japan "FUJITSU Server Information how to install, set up and operate PRIMERGY CX400 M6 your server enclosure, available online Server Enclosure Operating Manual" "FUJITSU Server Instructions for upgrading the server...
  • Page 22 – "iRMC S5 - Configuration and Maintenance" user guide – "iRMC S5 - Web Interface" user guide Infrastructure Manager "FUJITSU Software Infrastructure Manager documentation V2.6.0 Infrastructure Manager for PRIMEFLEX V2.6.0 User's Guide" ServerView documentation – "ServerView Suite Local Service Concept (LSC)"...
  • Page 23: Further Documents

    "保証書" for Japan printed copy "Returning used devices" Recycling and contact information, available manual online at https://ts.fujitsu.com/recycling, or as a printed copy "Service Desk" leaflet Not applicable in Japan and other countries that "サポート&サービス" for have different regulations for recycling...
  • Page 24 Before you start Document Description "D3893/D3894 BIOS Setup Information on configurable BIOS options and Utility for FUJITSU Server parameters, available online PRIMERGY CX2550 M6 / CX2560 M6 Server Node Reference Manual" Table 3: List of documents for the server nodes...
  • Page 25: Important Information

    Important information Introduction In this chapter you will find essential information regarding safety when working on your server enclosure. Depending on your server enclosure or the installed options some information is not valid for your server enclosure. CAUTION ▶ Before installing and starting up a server enclosure, please observe the safety instructions listed in the following section.
  • Page 26: Before Starting Up

    Important information ▶ Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment. ▶ Only valid for non hot-plug components Before installing/removing internal components to/from the server enclosure, turn off the server enclosure, all peripheral devices, and any other connected devices.
  • Page 27 Important information ▶ This server enclosure must only be connected to properly grounded power outlets or connected to the grounded rack internal power distribution server enclosure with tested and approved power cords. ▶ Ensure that the server enclosure is connected to a properly grounded power outlet close to the server enclosure.
  • Page 28 Important information ▶ In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), contact the server enclosure administrator or your customer service team. Only disconnect the server enclosure from the mains power supply if there is no risk of harming yourself. ▶...
  • Page 29: Batteries

    Important information ▶ The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. To ensure reliable protection, you must wear an earthing band on your wrist when working with this type of module and connect it to an unpainted, conducting metal part of the server enclosure.
  • Page 30: Working With Optical Disk Drives (Odds) And Media

    Important information ▶ All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant: ▶ Cd Cadmium ▶...
  • Page 31 Important information ▶ Before use, clean the ODD tray using a soft, dry cloth. ▶ As a precaution, remove disks from the ODD when the drive is not to be used for a long time. Keep the ODD tray closed to prevent foreign matter, such as dust, from entering the ODD.
  • Page 32: Laser Information

    Important information 3.2.6 Laser information The ODD complies with IEC 60825-1 laser class 1. CAUTION The ODD contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous. ▶...
  • Page 33: Transporting The Server Enclosure

    Important information ▶ Wear a suitable grounding cable that connects you to the external chassis of the server enclosure. ▶ Always hold ESD modules at the edges or at the points marked green (touch points). ▶ Do not touch any connectors or conduction paths on an ESD module. ▶...
  • Page 34: Installing The Server Enclosure In The Rack

    Important information 3.2.9 Installing the server enclosure in the rack CAUTION ▶ For safety reasons, at least 2 people are required to install the server enclosure in the rack because of its weight and size. (For Japan, see "安全上のご注意".) ▶ Never lift the server enclosure into the rack using the QRLs on the front panel.
  • Page 35: Energy Star

    ▶ Select the product class, e.g. "Industry Standard Servers". ▶ Select the subclass, e.g. "Cloud Server & Infrastruktur". ▶ Select your server, e.g. "PRIMERGY CX400 M6". ▶ Select the document, e.g. "CE Cert PRIMERGY CX400 M6". CX400 M6 Upgrade and Maintenance Manual...
  • Page 36: Fcc Class A Compliance Statement

    ▶ Consult the dealer or an experienced radio/TV technician for help. Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
  • Page 37: Environmental Protection

    Important information Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
  • Page 38 More information can be found at: https://ts.fujitsu.com/recycling Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch, or at: https://ts.fujitsu.com/recycling Upgrade and Maintenance Manual CX400 M6...
  • Page 39: Basic Hardware Procedures

    Basic hardware procedures Using diagnostic information 4.1.1 Proceeding Use the Fujitsu ServerView Suite management software to plan the upgrade or replacement of hardware components: ▶ In ServerView Operations Manager Single System View select Maintenance from the Information/Operation menu. It is recommended to prepare local maintenance tasks using remote diagnostics procedures, see the "ServerView Suite Local Service Concept...
  • Page 40: Determining The Error Class

    Basic hardware procedures Using the ServerView Operations Manager ▶ To toggle the ID indicator from the ServerView Operations Manager, choose Single System View and press the Locate button. Using the Infrastructure Manager ▶ To toggle the ID indicator from the Infrastructure Manager, select a node from the Node List screen and operate ID LED from the Action button.
  • Page 41: Shutting Down The Server

    Basic hardware procedures Possibilities to get more information about the defective component – Checking the ServerView System Monitor, available on Windows or Linux based servers with ServerView agents installed. For more information, see the "ServerView System Monitor" user guide. – Checking the System Event Log (SEL), see "Viewing and clearing the System Event Log (SEL)"...
  • Page 42: Disconnecting The Power Cord

    Basic hardware procedures ▶ Switch on the ID indicator on the front panel and I/O panel of the server, see "Locating the defective server" on page Disconnecting the power cord Before disconnecting the power cord all server nodes must be shut down.
  • Page 43: Removing Server Nodes From The Server Enclosure

    Basic hardware procedures Removing server nodes from the server enclosure The server enclosure must always run with closed node bays. It is only allowed to leave a bay open for a limited time in case of repairing a server node (for example). In the meantime all remaining server nodes run in throttling mode (with reduced performance).
  • Page 44 Basic hardware procedures Figure 4: Removing the CX2550 M6 or CX2560 M6 server node (B) ▶ Open the lever (1). When the lever is fully open, pull out the server node with the handle (2). Upgrade and Maintenance Manual CX400 M6...
  • Page 45: Removing The Server Node Dummy Module

    Basic hardware procedures Figure 5: Removing the CX2550 M6 or CX2560 M6 server node (C) ▶ Once the server node has been pulled to a position where the "Near to END" label (1) is visible, use the other hand to support the bottom of the server node until the server node has been pulled out.
  • Page 46: Installing Or Removing The Front Bezel

    Basic hardware procedures Figure 6: Removing the server node dummy module ▶ Undo the locking mechanism (1) of the release lever and pull the server node dummy module out of the bay (2). Installing or removing the front bezel Installing the brackets Figure 7: Front bezel overview Left and right bracket Upgrade and Maintenance Manual...
  • Page 47 Basic hardware procedures Left view Right view Figure 8: Installing the front bezel brackets ▶ Insert the brackets on the right and left side of the chassis front as shown (1). ▶ Fasten one screw on each side (see circles). Installing this bracket should only be done if the front bezel is installed for the first time.
  • Page 48 Basic hardware procedures ▶ If a key cylinder is attached to the front bezel, lock it (4). The front bezel is also available without a key cylinder. In this case, the key cylinder hole is capped. Removing the front bezel Figure 10: Removing the front bezel ▶...
  • Page 49: Getting Access To The Component

    Basic hardware procedures Getting access to the component 4.7.1 Safety notes CAUTION ▶ Only for non-hot plug components: ● Before removing or attaching covers, turn off the server, all peripheral devices, and any other connected devices. ● Because there is a risk of electric shock or damage, please disconnect all power cords from the outlet.
  • Page 50: Removing The Server Enclosure From The Rack

    Basic hardware procedures Figure 11: Extending the server enclosure out of the rack ▶ If the chassis is secured to the rack with screws, remove the screws (1). ▶ While pressing the locking levers (2) on both sides of the enclosure use the brackets (3) to pull the enclosure out of the rack.
  • Page 51 Basic hardware procedures CAUTION At least two people are needed to lift the server enclosure out of the rack cabinet. (For Japan, see " 安全上のご注意".) For configurations below 32 kg: At least two people are needed to lift the server enclosure out of the rack cabinet.
  • Page 52 Basic hardware procedures When not using a cable management arm Figure 12: Removing the server enclosure from the rack (A) ▶ Pull the server enclosure out of the rack as far as it will go (1). ▶ Release the locking springs on both rack rails (2). When using a cable management arm Figure 13: Removing the server enclosure from the rack (A) ▶...
  • Page 53 Basic hardware procedures Figure 14: Unlocking the locking springs If you are using a cable management arm, perform the following steps: ▶ Release the locking springs on both sides of the rack rail by pressing the shift bracket (1). ▶ Remove the springs that are locking the rack rails on both sides (2). Figure 15: Removing the server enclosure from the rack (B) CX400 M6 Upgrade and Maintenance Manual...
  • Page 54: Removing The Top Covers

    Basic hardware procedures ▶ Pull out the chassis from the outer rails. Remove the server enclosure from the rack carefully. Must be done with at least two people. 4.7.4 Removing the top covers Removing the fan cover Figure 16: Removing the fan cover from the chassis ▶...
  • Page 55 Basic hardware procedures Removing the middle top cover Figure 17: Removing the middle top cover from the chassis ▶ Make sure that the fan cover is removed, see "Removing the fan cover" on page ▶ Remove two screws from the middle top cover (see circles). ▶...
  • Page 56: Reassembling

    Basic hardware procedures Reassembling CAUTION ▶ Before attaching the covers, make sure no unnecessary parts or tools are left inside the server. ▶ The top cover must be replaced as soon as possible for purposes of cooling, to comply with EMC regulations (regulations regarding electromagnetic compatibility) and to prevent fires.
  • Page 57 Basic hardware procedures Figure 19: Installing the middle top cover on the chassis (B) ▶ Fasten the middle top cover with the two original screws (#6-32) (see circles). CX400 M6 Upgrade and Maintenance Manual...
  • Page 58 Basic hardware procedures Installing the fan cover Figure 20: Installing the fan cover on the chassis ▶ Insert the fan cover as shown (1). ▶ Shift the locking tabs in the direction of the arrows (2) and flip down the cover (3).
  • Page 59: Installing The Rack Rails

    Basic hardware procedures 4.8.2 Installing the rack rails Removing the inner rail from the rack rails Figure 21: Inner and outer rail ▶ Identify the inner (2) rail and the outer rail (1). Figure 22: Starting position of inner and outer rail CX400 M6 Upgrade and Maintenance Manual...
  • Page 60 Basic hardware procedures ▶ Push the lever (1) and pull the inner rail as far as possible towards the front side (2). Figure 23: Turning outer rail ▶ Turn the rails to the other side. Figure 24: Removing inner rail from outer rail Upgrade and Maintenance Manual CX400 M6...
  • Page 61 Basic hardware procedures ▶ Push the locking latch (1) and pull the outer rail as far as possible towards the front side (2). Now the inner rail is removed from the outer rail. Attaching the rack rails to the server enclosure ▶...
  • Page 62 Basic hardware procedures ▶ Snap the right rack rail support holes into the chassis T-shaped pins (1) and slide forward (2). Figure 27: Adjusting the rack rail ▶ Fasten the rack rail with two M4 screws (see circles). ▶ Repeat this procedure to install the left rack rail. Installing the rack rails ▶...
  • Page 63 Basic hardware procedures Figure 28: Attaching the left rack rail ▶ Move the left rack rail towards the rear side (2) while holding the positioning clip (1). The mounting aid must lock in the corresponding hole. ▶ Release the positioning clip (1) after the designated position is reached. ▶...
  • Page 64: Installing The Server Enclosure In The Rack

    Basic hardware procedures Repeat this procedure to install the left and right rail. Figure 30: Fastening the screw ▶ Tighten the M5 screw on the rear side of the rail (see circles). 4.8.3 Installing the server enclosure in the rack CAUTION At least two people are needed to position the server enclosure on the rack rails.
  • Page 65 Basic hardware procedures For configurations below 32 kg: At least two people are needed to lift the server enclosure into the rack cabinet. For configurations below 55 kg: At least three people are needed to lift the server enclosure into the rack cabinet. For configurations above 55 kg: At least four people are needed to lift the server enclosure into the rack cabinet.
  • Page 66 Basic hardware procedures Figure 31: Fixing the shift bracket ▶ Attach the left and right shift bracket to the rack pillar and secure them with the studs (1) that are supplied to the shift brackets. It is also ok to use other screws that are supplied to the shift bracket in order to attach the shift bracket.
  • Page 67 Basic hardware procedures Figure 32: Mounting the server enclosure into the rack (A) ▶ Slide the server enclosure into the rack until it is locked by the latch. Figure 33: Removing the shift bracket CX400 M6 Upgrade and Maintenance Manual...
  • Page 68: Sliding The Server Enclosure Into The Rack

    Basic hardware procedures ▶ Remove the stud (1) and then remove the shift bracket. Required tool: For the stud: Hexagon screw driver SW7, flat-head screw driver. For the other screws: Phillips PH2 / (+) No. 2 screw driver. This only applies if the target chassis is not using the CMA. When using the CMA, do not remove the shift bracket.
  • Page 69 Basic hardware procedures When using a CMA Figure 35: Mounting the server enclosure into the rack (B) ▶ Push the server enclosure into the rack. ▶ When the server enclosure stops, push the locking latch (1) on both sides and push the server enclosure into the rack (2). ▶...
  • Page 70: Installing The Cable Management Arm (Cma)

    Basic hardware procedures Figure 36: Mounting the server enclosure into the rack (C) ▶ Push the enclosure into the rack (1) until the locking mechanism engages. ▶ If the chassis was originally secured with screws, re-secure the chassis with screws (2). 4.8.5 Installing the cable management arm (CMA) Parts of the CMA...
  • Page 71 Basic hardware procedures Figure 38: Example of a CMA kit part The upper figure shows the left side of the CMA. You can distinguish the sides by the engraving on the upper left part. Figure 39: CMA - Accompanying items (A) Left side: shift bracket Spacer Right side: shift bracket...
  • Page 72 Basic hardware procedures Figure 40: CMA - Accompanying items (B) Cage nut (RMK) Velcro tape (RMK) points at the accompanying items of the rack mounting kit. Figure 41: CMA bracket position (left and right side) Cage nut Shift bracket Screw Spacer Upgrade and Maintenance Manual CX400 M6...
  • Page 73 Basic hardware procedures Installing the CMA Tools: Phillips PH2 / (+) No. 2 screw driver, hexagon screw driver (7 mm) ▶ Install the brackets on the front side of the rack with the screws. Figure 42: Connection points for the right side of the CMA Connected to the outer side connector Connected to the inner side connector of the CMA...
  • Page 74 Basic hardware procedures Figure 43: Installing the right side of the CMA to the RMK Outer side connector of the CMA Inner side connector of the CMA Right side: CMA ▶ Install the CMA to the rear side of the RMK. There are two latches for each side of the CMA.
  • Page 75 Basic hardware procedures CMA cable routing Figure 45: Slot position ▶ Rearrange the cables for the server nodes in slot 1 and slot 2 in the right side of the CMA. ▶ Rearrange the cables for the server nodes in slot 3 and slot 4 in the left side of the CMA.
  • Page 76 Basic hardware procedures ▶ Fix all the cables except for the PSU cable to the CMA on the left and right side. Figure 47: Fixing the PSU cable ▶ Tighten the clamp as tightly as possible (1). Also ensure that the clamp is fixed as close to the PSU as possible.
  • Page 77 Basic hardware procedures Figure 49: Overview of the cable routing ▶ Fix the PSU cable just like the other cables to the CMA-R (or/and the CMA- Figure 50: Installing the CMA stopper ▶ Install the CMA stopper to the rear side of the RMK (see circles). CX400 M6 Upgrade and Maintenance Manual...
  • Page 78 Basic hardware procedures Figure 51: Latch positions of the CMA There is a latch on each side of the RMK. Figure 52: Note on routing the PSU cable ▶ If the PSU cable interferes with the CMA, the cables secured to the CMA, or the CMA stopper, adjust the securing of the PSU cable to eliminate the interference.
  • Page 79 Basic hardware procedures Conditions after cables are formed Figure 53: Note on cable condition ▶ Ensure that the cables are properly aligned and don't hang down. Figure 54: Fixing the cables with a velcro tape CX400 M6 Upgrade and Maintenance Manual...
  • Page 80: Installing The Server Node Dummy Module

    Basic hardware procedures ▶ To prevent the cables from hanging down, the cables may be bundled with a velcro tape (1). Installing the server node dummy module CAUTION ▶ Follow the safety instructions in "Important information" on page Figure 55: Installing the server node dummy module ▶...
  • Page 81: Installing Server Nodes In The Server Enclosure

    Basic hardware procedures 4.10 Installing server nodes in the server enclosure Server node and PSU bay numbering Figure 56: CX400 M6 server node and PSU bay numbering (rear view) Server node bay 1 Server node bay 4 Server node bay 2 PSU 1 Server node bay 3 PSU 2...
  • Page 82 Basic hardware procedures Installing the CX2550 M6 or CX2560 M6 server node CAUTION ▶ Follow the safety instructions in "Important information" on page Figure 57: Pushing the server node into the server enclosure (A) ▶ Push the server node into the chassis while holding the handle (1) and use the lever to engage it (2).
  • Page 83 Basic hardware procedures Figure 58: Pushing the server node into the server enclosure (B) ▶ Ensure that the locking mechanism of the lever tip snaps into place (see circle). ▶ If applicable, connect all external cables to the server node. ▶...
  • Page 84: Connecting The Power Cord

    Basic hardware procedures 4.11 Connecting the power cord Connecting the power cord (AC PSU) CAUTION The AC PSU adjusts automatically to any mains voltage in the range from 100 V - 127 V or 200 V - 240 V. ▶ You may only operate the server enclosure if its rated voltage range corresponds to the local mains voltage.
  • Page 85 Basic hardware procedures ▶ If applicable, connect the mains plugs to power outlets of the rack socket strip. To provide true phase redundancy, the second PSU should be connected to a different AC power source from the other PSU. If one AC power source should fail, the server enclosure will still continue to run.
  • Page 86: Switching On The Server Nodes

    Basic hardware procedures 4.12 Switching on the server nodes CAUTION ▶ Follow the safety instructions in "Important information" on page Controls and indicators are the same for the CX2550 M6 and the CX2560 M6. ▶ If applicable, connect all external cables to the server node. Figure 61: Controls and indicators of the server node ID indicator On/Off button / Power-on indicator...
  • Page 87: Basic Software Procedures

    Basic software procedures Starting the maintenance task 5.1.1 Switching on the ID indicator For easy identification of the server, switch on the ID indicator, especially when working in a datacenter environment or a server room. The ID indicator can also be activated via the iRMC S5 web interface and its status is reported to the iRMC S5.
  • Page 88: Completing The Maintenance Task

    (SEL)" on page When using the Infrastructure Manager, please refer to the following manuals about backup and restore function of system information. See manual "FUJITSU Software Infrastructure Manager Vx.x.x User's Guide", section "2.10 Backup/Restore Hardware Settings", available at: https://ts.fujitsu.com/support/ For Japan: See manual "FUJITSU Software Infrastructure Manager Vx.x.x 解説書",...
  • Page 89: Performing A Raid Array Rebuild

    Basic software procedures After replacing the power distribution board of the chassis ▶ Check the SEL log file to verify whether the system information for the chassis has been restored, see "Viewing and clearing the System Event Log (SEL)" on page Chassis IDPROM: BMC FW backup successful Automatic restore of chassis FRU data from backup file finished successfully.
  • Page 90: Switching Off The Id Indicator

    Basic software procedures Figure 62: Progress bar (RAID array rebuild) CAUTION The system is now operational, however, data redundancy will not be available until the RAID array rebuild is complete. Depending on the HDD capacity the overall process can take up to several hours, in some cases even days.
  • Page 91: Viewing And Clearing The System Event Log (Sel)

    Basic software procedures Using the ID icon in the iRMC S5 web interface ▶ Log in to the iRMC S5 web interface. The icon that represents the ID indicator LED resides on the right of the menu bar. Its color symbolizes its status: blue: the ID LED is on.
  • Page 92 Basic software procedures ▶ Select the message type(s) you want to display: ‐ Critical events ‐ Major events ‐ Minor events ‐ Informational events Note on the Driver Monitor of the ServerView Operations Manager The Driver Monitor view gives you an overview of the monitored components as well as the associated events contained in the system event log on the managed server.
  • Page 93 Basic software procedures Note on the Driver Monitor of the iRMC S5 web interface The Driver Monitor view gives you an overview of the monitored components. If a component has the status Warning or Error, you can click Reset status. You have to log on to the iRMC S5 web interface beforehand. The status of the component will then be reset to ok.
  • Page 94: Performing A Fan Test

    Basic software procedures Please refer to the following manuals of Infrastructure Manager for collecting logs from ISM. See manual "FUJITSU Software Infrastructure Manager Vx.x.x User's Guide", section "2.5 Log Management", available at: https://ts.fujitsu.com/support/ For Japan: See manual "FUJITSU Software Infrastructure Manager Vx.x.x 解説書", section "2.5 ログ管理機能", available at:...
  • Page 95: Updating Server View Raid Manager

    ▶ After the fan test is complete, restore the time setting to its initial value and click Save Page. In case of maintenance done by Fujitsu engineers in Japan: Executing the fan test via Chassis ID Prom Tool Please follow the instructions provided separately.
  • Page 96: Using The Chassis Id Prom Tool

    "Verifying system information backup or restore" on page Update your system information using the Chassis ID Prom tool. The tool and further instructions are available to maintenance personnel from the Fujitsu Technology Solutions Extranet: https://partners.ts.fujitsu.com/com/service/ps/Servers/PRIMERGY/ ▶ Select your PRIMERGY system from the main area of the page.
  • Page 97: Power Supply Unit (Psu)

    Power supply unit (PSU) Safety notes CAUTION ▶ Do not disassemble the PSU. Doing so may cause electric shock. ▶ Areas around the PSU may remain extremely hot after shutdown. After shutting down the server, wait for hot components to cool down before removing the PSU.
  • Page 98 Power supply unit (PSU) PSU configurations Figure 63: Example of Titanium PSU 2600 W Assembly rules ● Mixed assembly of PSUs of different power classes (e.g. class 1 or class 2) within a server enclosure is not supported. ● Mixing of Platinum and Titanium PSUs within same class (e.g. class 2) within a server enclosure is not supported.
  • Page 99: Replacing The Hot-Plug Psu

    Power supply unit (PSU) PSU bays PSU 2 PSU 1 Figure 64: PSU bays Replacing the hot-plug PSU Customer Replaceable Hardware: 5 minutes Unit (CRU) Tools: tool-less CAUTION ▶ When replacing a PSU in a non-redundant PSU configuration, the server must be switched off first. ▶...
  • Page 100 Power supply unit (PSU) The power supply of the server node does not need not be turned off. Removing the defective hot-plug PSU Figure 65: Removing the PSU ▶ Push the handle of the PSU halfway downward in the direction of the arrow (1).
  • Page 101 Power supply unit (PSU) Installing the new hot-plug PSU Figure 66: Inserting the cable clamp ▶ The PSU does not have a cable clamp at first use. Insert the cable clamp into the hole of the PSU as shown. CX400 M6 Upgrade and Maintenance Manual...
  • Page 102 Power supply unit (PSU) Figure 67: Pushing the PSU latch ▶ Push the latch of the hot-plug PSU in the direction of the arrow. Figure 68: Installing the hot-plug PSU ▶ Carefully push the hot-plug PSU into the empty bay until it stops (1). ▶...
  • Page 103: Removing/Installing The Psu Dummy Module

    Power supply unit (PSU) Ensure that the PSU engages correctly in the bay and is locked in position. This is the only way to prevent the PSU from sliding out of its bay and being damaged during transportation. Concluding steps ▶...
  • Page 104 Power supply unit (PSU) Removing the PSU dummy module Figure 69: Removing the PSU dummy module ▶ Press in on both release latches (1) and remove the PSU dummy module in the direction of the arrows (2). Upgrade and Maintenance Manual CX400 M6...
  • Page 105 Power supply unit (PSU) Installing the PSU dummy module Figure 70: Installing the PSU dummy module ▶ Insert the PSU dummy module in the empty bay until it stops. CX400 M6 Upgrade and Maintenance Manual...
  • Page 106 Power supply unit (PSU) Upgrade and Maintenance Manual CX400 M6...
  • Page 107: Hard Disk Drive (Hdd) / Solid State Disk (Ssd)

    Hard disk drive (HDD) / solid state disk (SSD) Safety notes CAUTION ▶ Before removing several HDD/SSD modules, make sure that all HDD/SSD modules can be reinstalled into their original bay. Otherwise, data may be lost. ▶ Do not touch the circuitry on boards or soldered parts. Hold circuit boards by their metallic areas or edges.
  • Page 108: Basic Information

    Hard disk drive (HDD) / solid state disk (SSD) Basic information HDDs/SSDs Using CX2550 M6 server nodes, the server enclosure can be equipped with a maximum of 8 x 2.5 " HDD/SSD modules. Using CX2560 M6 server nodes, the server enclosure can be equipped with a maximum of 24 x 2.5 "...
  • Page 109 Hard disk drive (HDD) / solid state disk (SSD) CX400 M6 equipped with CX2560 M6 server nodes Node 4 PSU 2 Node 2 Node 3 PSU 1 Node 1 Table 7: Server nodes and PSUs (rear view) 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 Node 1 Node 2 Node 3...
  • Page 110 Hard disk drive (HDD) / solid state disk (SSD) Figure 72: HDD backplane 1-2 and HDD backplane 1-3 (6x HDDs) HDD backplane 1-1 (A3C40233568) provides 2 SAS/SATA/ PCIe SSD combi connectors (0, 1). This backplane is used with CX2550 M6 server nodes. HDD backplane 1-2 (A3C40233567) provides 4 SAS/SATA connectors (0, 1, 2, 3) and two SAS/SATA/PCIe SSD combi connectors (4, 5).
  • Page 111 Hard disk drive (HDD) / solid state disk (SSD) Figure 73: Configuration with type A (HDD backplane 1-1) (0) ... (1) SAS/SATA/ PCIe SSD Figure 74: Configuration with type B (HDD backplane 1-2) (0) ... (3) SAS/SATA (4) ... (5) SAS/SATA/PCIe SSD Figure 75: Configuration with type C (HDD backplane 1-3) (0) ...
  • Page 112: Installing 2.5-Inch Hdd/Ssd Modules

    Hard disk drive (HDD) / solid state disk (SSD) Figure 76: Configuration with HDD/SSD x6 front bezels HDD/SSD x6 front bezel Figure 77: Configuration with HDD/SSD 4x front bezel HDD/SSD 4x front bezel (only for CX2550 M6 Instead, four HDD/SSD dummy modules can also be installed. Installing 2.5-inch HDD/SSD modules Customer Replaceable Hardware: 5 minutes...
  • Page 113 Hard disk drive (HDD) / solid state disk (SSD) Preliminary steps ▶ If applicable, remove the front bezel, see "Removing the front bezel" on page ▶ Locate the correct drive bay, see "HDD/SSD bays assignment" on page 108. Removing a 2.5-inch HDD/SSD dummy module Figure 78: Removing a 2.5-inch HDD/SSD dummy module ▶...
  • Page 114 Hard disk drive (HDD) / solid state disk (SSD) Installing a 2.5-inch HDD/SSD module Figure 79: Opening the locking lever ▶ Pinch the green locking clips (1) and open the locking lever (2). Figure 80: Installing the 2.5-inch HDD/SSD module ▶...
  • Page 115: Removing 2.5-Inch Hdd/Ssd Modules

    Hard disk drive (HDD) / solid state disk (SSD) ▶ When using a RAID array, add the additional HDD/SSD to the RAID array. Configuring the RAID array, see the documentation of the RAID controller, used in your configuration, see "Documentation overview" on page Concluding steps ▶...
  • Page 116 Hard disk drive (HDD) / solid state disk (SSD) RAID level Procedure RAID 0 CAUTION RAID 0 provides no data redundancy. In case of an HDD module is defect, all data are lost! RAID 1 Removing an HDD/SSD module from a RAID 1 or RAID 5 array will not result in data loss.
  • Page 117 Hard disk drive (HDD) / solid state disk (SSD) ▶ Pull the HDD/SSD module completely out of its bay. Installing a 2.5-inch dummy module CAUTION ▶ If the removed HDD/SSD module is not replaced immediately, always replace a dummy module into the unused HDD/SSD bay to comply with applicable EMC regulations and satisfy cooling requirements.
  • Page 118: Replacing A 2.5-Inch Hdd/Ssd Module

    Hard disk drive (HDD) / solid state disk (SSD) Replacing a 2.5-inch HDD/SSD module Customer Replaceable Hardware: 5 minutes Unit (CRU) Tools: Preliminary and concluding steps: tool-less Main steps: tool-less CAUTION ▶ Only remove an HDD/SSD module during operation if the drive is not currently being accessed.
  • Page 119: Replacing A 2.5-Inch Hdd/Ssd Backplane

    Hard disk drive (HDD) / solid state disk (SSD) Preliminary steps ▶ "Locating the defective server" on page ▶ If applicable, remove the front bezel, see "Removing the front bezel" on page ▶ "Locating the defective component" on page Removing the defective 2.5-inch HDD/SSD module ▶...
  • Page 120 Hard disk drive (HDD) / solid state disk (SSD) Preliminary steps ▶ Shut down the server nodes, see "Shutting down the server" on page ▶ "Disconnecting the power cord" on page ▶ If the server node is installed in server node bay 2 and/or 4, remove it, see "Removing server nodes from the server enclosure"...
  • Page 121 Hard disk drive (HDD) / solid state disk (SSD) Figure 83: Disconnecting the PDB (B) ▶ Pull the cable out of the chassis as shown. Figure 84: Removing the fan cage CX400 M6 Upgrade and Maintenance Manual...
  • Page 122 Hard disk drive (HDD) / solid state disk (SSD) ▶ If applicable, remove the screws securing the fan cage to the backplane holders (1). ▶ Loosen the screws that secure the fan cage from both sides (2). ▶ Lift the fan cage out of the enclosure (3). ▶...
  • Page 123 Hard disk drive (HDD) / solid state disk (SSD) Figure 86: Removing the 2.5-inch HDD backplane ▶ Carefully pull up on the backplane in a vertical motion and remove it from its slot (1). CX400 M6 Upgrade and Maintenance Manual...
  • Page 124 Hard disk drive (HDD) / solid state disk (SSD) Installing the 2.5-inch HDD backplane Figure 87: Installing the 2.5-inch HDD backplane ▶ Align the backplane module with the pins on both sides of the connectors of the backplane (see circle). ▶...
  • Page 125 Hard disk drive (HDD) / solid state disk (SSD) Figure 88: Connecting the cable to the backplane ▶ Connect the cable to the connector on the bridge board side of the cable (1). However, if the cable is already connected, this operation does not need to be performed.
  • Page 126 Hard disk drive (HDD) / solid state disk (SSD) Installing the fan cage Figure 89: Installing the backplane holder ▶ Insert the backplane holder as shown (1) and place it on the backplane module (2). ▶ Align the two holes on the backplane holder with the protrusions on the top of the backplane module.
  • Page 127 Hard disk drive (HDD) / solid state disk (SSD) Figure 90: Inserting the fan cage ▶ Carefully insert the fan cage in the chassis. Figure 91: Fastening the fan cage ▶ Fasten the fan cage with two screws on each side (see circle). CX400 M6 Upgrade and Maintenance Manual...
  • Page 128 Hard disk drive (HDD) / solid state disk (SSD) Figure 92: Note on fan cage installation Fasten the screw while pushing the fan cage so that the edge of the fan cage does not leap over from the edge of the chassis. Figure 93: Fastening the fan cage ▶...
  • Page 129 Hard disk drive (HDD) / solid state disk (SSD) Figure 94: Connecting the cables to the PDB ▶ Connect each cable to the PDB. Also, fasten the cables with a clamp (see circles). Figure 95: Placing the cables ▶ Place the cables in the space on each side of the fan cage. CX400 M6 Upgrade and Maintenance Manual...
  • Page 130: Installing Or Removing The Hdd/Ssd Bridge Board

    Hard disk drive (HDD) / solid state disk (SSD) Concluding steps ▶ Install the fan modules, see "Installing the fan module" on page 148. ▶ "Installing the new high speed riser module" on page 153. ▶ "Installing the top covers" on page ▶...
  • Page 131 CAUTION Installing procedures involving Upgrade and Repair Units must be performed exclusively by Fujitsu service personnel or technicians trained by Fujitsu. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.
  • Page 132 Hard disk drive (HDD) / solid state disk (SSD) Removing the HDD/SSD bridge board Figure 96: Removing the HDD/SSD bridge board ▶ Remove the two hexagonal spacers (1). ▶ Remove the air duct (2). ▶ Remove the screws securing the HDD/SSD bridge board (3). Upgrade and Maintenance Manual CX400 M6...
  • Page 133 Hard disk drive (HDD) / solid state disk (SSD) Figure 97: Removing the HDD/SSD bridge board ▶ Carefully lift up the HDD/SSD bridge board in the direction of the arrow. CX400 M6 Upgrade and Maintenance Manual...
  • Page 134 Hard disk drive (HDD) / solid state disk (SSD) Installing the HDD/SSD bridge board Figure 98: Installing the HDD/SSD bridge board ▶ Use the two guide pins on the chassis to align the bridge board and slowly place it into the chassis (1). ▶...
  • Page 135: Replacing The Hdd/Ssd Bridge Board

    Hard disk drive (HDD) / solid state disk (SSD) ▶ "Installing the top covers" on page ▶ "Sliding the server enclosure into the rack" on page ▶ Install all HDD/SSD modules in the relevant HDD/SSD cages, see "Installing a 2.5-inch HDD/SSD module" on page 114.
  • Page 136 Hard disk drive (HDD) / solid state disk (SSD) ▶ Remove all HDD/SSD modules from the relevant HDD/SSD cage, see "Removing a 2.5-inch HDD/SSD module" on page 116. ▶ If applicable, remove all 2.5-inch HDD/SSD dummy module, see "Removing a 2.5-inch HDD/SSD dummy module" on page 113.
  • Page 137 Hard disk drive (HDD) / solid state disk (SSD) ▶ Remove the two hexagonal spacers (1). ▶ Remove the air duct (2). ▶ Remove the screws securing the HDD/SSD bridge board (3). Figure 100: Removing the HDD/SSD bridge board ▶ Carefully lift up the HDD/SSD bridge board in the direction of the arrow. CX400 M6 Upgrade and Maintenance Manual...
  • Page 138 Hard disk drive (HDD) / solid state disk (SSD) Installing the HDD/SSD bridge board Figure 101: Installing the HDD/SSD bridge board ▶ Use the two guide pins on the chassis to align the bridge board and slowly place it into the chassis (1). ▶...
  • Page 139: Changing Hdd/Ssd Cage Bezels

    Hard disk drive (HDD) / solid state disk (SSD) ▶ "Installing the top covers" on page ▶ "Sliding the server enclosure into the rack" on page ▶ Install all HDD/SSD modules in the relevant HDD/SSD cages, see "Installing a 2.5-inch HDD/SSD module" on page 114.
  • Page 140 Hard disk drive (HDD) / solid state disk (SSD) ▶ If applicable, remove all 2.5-inch HDD/SSD dummy module, see "Removing a 2.5-inch HDD/SSD dummy module" on page 113. ▶ "Extending the server enclosure out of the rack" on page Removing the HDD/SSD x6 front bezel Figure 102: Removing the front bezel fixing screw ▶...
  • Page 141 Hard disk drive (HDD) / solid state disk (SSD) ▶ Grasp behind the HDD slot through the hole (see circle). ▶ Push from the back to release the front bezel. Removing the HDD/SSD x4 front bezel Figure 104: Removing the front bezel fixing screw ▶...
  • Page 142 Hard disk drive (HDD) / solid state disk (SSD) Installing the HDD/SSD x6 front bezel Figure 106: Installing the front bezel (A) ▶ Hook the front bezel onto the bottom of the empty cage and rotate it as shown by the arrows to snap it into the cage. Figure 107: Installing the front bezel (B) ▶...
  • Page 143 Hard disk drive (HDD) / solid state disk (SSD) Figure 108: Installing the front bezel (A) ▶ Hook the front bezel onto the bottom of the empty cage and rotate it as shown by the arrows to snap it into the cage. Figure 109: Installing the front bezel (B) ▶...
  • Page 144 Hard disk drive (HDD) / solid state disk (SSD) Concluding steps ▶ If applicable, install the HDD/SSD modules you removed before, see "Installing a 2.5-inch HDD/SSD module" on page 114. ▶ If applicable, install the 2.5-inch HDD/SSD dummy modules into the relevant cage, see "Installing a 2.5-inch dummy module"...
  • Page 145: Fans

    ▶ For more information, see "Important information" on page Basic information The PRIMERGY CX400 M6 server enclosure features five hot-plug fan modules. Fan positions Figure 110 shows the position of the system fans 1 to 5.
  • Page 146: Replacing A Fan Module

    Fans Front Figure 110: Fan positions Replacing a fan module Field Replaceable Unit Hardware: 5 minutes (FRU) Tools: Preliminary and concluding steps: Phillips PH2 / (+) No. 2 hexagonal cross SW5 / PZ2 Main steps: tool-less Preliminary steps ▶ If applicable, remove the front bezel, see "Removing the front bezel"...
  • Page 147 Fans ▶ Locate the defective fan module using the diagnostic panel on the cover of the server enclosure (see "Fan indicators" on page 203). Removing the fan module Figure 111: Removing the fan module ▶ Pinch the handles (1) on both sides to release the lock and lift it up (2). CAUTION The fan blade rotates by inertia.
  • Page 148 Fans Installing the fan module Figure 112: Installing the fan module ▶ Carefully insert the fan module into the bay and press down firmly until it is fully seated in the bay. Concluding steps ▶ "Installing the fan cover" on page ▶...
  • Page 149: High Speed Riser Module

    High speed riser module Safety notes CAUTION ▶ Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. ▶ Devices and components inside the server remain hot after shutdown. After shutting down the server, wait for hot components to cool down before installing or removing internal options.
  • Page 150: Replacing A High Speed Riser Module

    High speed riser module Figure 113: High speed riser module (A3C40233545) Replacing a high speed riser module Field Replaceable Unit Hardware: 5 minutes (FRU) Tools: Phillips PH2 / (+) No. 2 screw driver Preliminary steps ▶ "Locating the defective server" on page ▶...
  • Page 151 High speed riser module Removing the defective high speed riser module Figure 114: Loosening the high speed riser module ▶ Loosen the two screws (see circles) of the corresponding high speed riser module. CX400 M6 Upgrade and Maintenance Manual...
  • Page 152 High speed riser module Figure 115: Removing the high speed riser module ▶ Unlock the lever tip and use the lever to remove the high speed riser module from the bridge board (1). Then, lift the high speed riser module like that (2). Upgrade and Maintenance Manual CX400 M6...
  • Page 153 High speed riser module Installing the new high speed riser module Figure 116: Installing the high speed riser module ▶ Insert the high speed riser module between FAN1 and FAN2 and FAN4 and FAN 5 as shown. ▶ Place the high speed riser module on the connector guide pin on the bridge board and the guide pin on the power distribution board.
  • Page 154 High speed riser module Figure 117: Fastening the high speed riser module ▶ Fasten the corresponding high speed riser module with two screws (see circles). Concluding steps ▶ "Installing the top covers" on page ▶ "Sliding the server enclosure into the rack" on page ▶...
  • Page 155: Power Distribution Board

    Power distribution board 10.1 Safety notes CAUTION ▶ Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. ▶ Devices and components inside the server remain hot after shutdown. After shutting down the server, wait for hot components to cool down before installing or removing internal options.
  • Page 156: Removing The Power Distribution Board Kit

    Power distribution board Figure 118: Power distribution board (A3C40233535) 10.3 Removing the power distribution board kit Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: Phillips PH2 / (+) No. 2 hexagonal cross SW5 / PZ2 Main steps: tool-less Preliminary steps ▶...
  • Page 157 Power distribution board ▶ "Removing the defective high speed riser module" on page 151. ▶ "Removing the fan module" on page 147. ▶ "Removing the fan cage" on page 120. Removing the power distribution board kit Figure 119: Removing the screws ▶...
  • Page 158 Power distribution board Figure 120: Removing the power distribution board kit ▶ Lift the power distribution board kit in the direction of the arrow (1). ▶ Remove the power distribution board kit upward without colliding with the protrusions inside the chassis (2). Removing the power distribution board Figure 121: Loosening the power distribution board ▶...
  • Page 159: Installing The Power Distribution Board Kit

    Power distribution board Figure 122: Removing the power distribution board ▶ Remove the power distribution board from the installation bolts and stand-off pins (see circles). 10.4 Installing the power distribution board kit Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: Phillips PH2 / (+) No.
  • Page 160 Power distribution board Installing the power distribution board Figure 123: Aligning the power distribution board ▶ Align the power distribution board on the two stand-off pins (see circles). ▶ Place the power distribution board on the installation bolts and stand-off pins.
  • Page 161 Power distribution board Installing the power distribution board kit Figure 125: Installing the power distribution board kit ▶ Insert the power distribution board kit as shown and move it in the direction of the arrow with avoiding the emboss of the chassis (1). ▶...
  • Page 162 Power distribution board Figure 126: Fastening the screws ▶ Fasten the power distribution board kit with four screws (see circle). ▶ Place the air duct on the power distribution board kit. ▶ Fasten the air duct with two screws. Concluding steps ▶...
  • Page 163: Replacing The Power Distribution Board

    Power distribution board ▶ "Connecting the power cord" on page ▶ "Switching on the server nodes" on page ▶ "Verifying system information backup or restore" on page 10.5 Replacing the power distribution board Field Replaceable Unit Hardware: 30 minutes (FRU) Tools: Preliminary and concluding steps: Phillips PH2 / (+) No.
  • Page 164 Power distribution board Installing the PDB kit ▶ Install the new PDB kit, see "Installing the power distribution board kit" on page 159. Concluding steps ▶ "Installing the fan cage" on page 126. ▶ "Installing the fan module" on page 148.
  • Page 165: Front Panel

    Front panel 11.1 Safety notes CAUTION ▶ When inserting the front panel module into the server enclosure, ensure not to pinch or strain any connected cables. ▶ Circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Always discharge static build-up (e.g.
  • Page 166 Front panel ▶ "Extending the server enclosure out of the rack" on page ▶ "Removing the top covers" on page Removing the front panel Figure 127: Loosening the front panel (A) ▶ Pull the cable from the side of the fan cage. Figure 128: Loosening the front panel (B) Upgrade and Maintenance Manual CX400 M6...
  • Page 167 Front panel ▶ Loosen the front panel by removing two screws (see circles). Figure 129: Disconnecting the front panel ▶ Disconnect the front panel cable from the front panel (see circle). CX400 M6 Upgrade and Maintenance Manual...
  • Page 168 Front panel Installing the front panel Figure 130: Connecting the front panel ▶ Connect the front panel cable to the front panel (see circle). Upgrade and Maintenance Manual CX400 M6...
  • Page 169 Front panel Figure 131: Securing the front panel (A) ▶ Fasten the front panel with two screws (see circles). CX400 M6 Upgrade and Maintenance Manual...
  • Page 170: Replacing The Right Front Panel Module

    Front panel Figure 132: Securing the front panel (B) ▶ Place the cable in the space on the side of the fan cage as shown. Concluding steps ▶ "Installing the top covers" on page ▶ "Sliding the server enclosure into the rack" on page ▶...
  • Page 171 Front panel Preliminary and concluding steps: tool-less Tools: Main steps: Phillips PH2 / (+) No. 2 Preliminary steps ▶ "Shutting down the server" on page ▶ "Disconnecting the power cord" on page ▶ If applicable, remove the front bezel, see "Removing the front bezel"...
  • Page 172 Front panel Figure 134: Loosening the front panel (B) ▶ Loosen the front panel by removing two screws (see circles). Upgrade and Maintenance Manual CX400 M6...
  • Page 173 Front panel Figure 135: Disconnecting the front panel ▶ Disconnect the front panel cable from the front panel (see circle). CX400 M6 Upgrade and Maintenance Manual...
  • Page 174 Front panel Installing the front panel Figure 136: Connecting the front panel ▶ Connect the front panel cable to the front panel (see circle). Upgrade and Maintenance Manual CX400 M6...
  • Page 175 Front panel Figure 137: Securing the front panel (A) ▶ Secure the front panel with two screws (see circles). CX400 M6 Upgrade and Maintenance Manual...
  • Page 176 Front panel Figure 138: Securing the front panel (B) ▶ Place the cable in the space on the side of the fan cage as shown. Concluding steps ▶ "Installing the top covers" on page ▶ "Sliding the server enclosure into the rack" on page ▶...
  • Page 177: Front Panel Cable

    Front panel 11.3 Front panel cable 11.3.1 Replacing the left front panel cable Field Replaceable Unit Hardware: 30 minutes (FRU) Tools: Preliminary and concluding steps: Phillips PH2 / (+) No. 2 Main steps: tool-less Preliminary steps ▶ "Shutting down the server" on page ▶...
  • Page 178 Front panel Removing the left front panel cable ▶ Remove the left front panel, see "Removing the front panel" on page 166. Figure 139: Removing the left front panel cable (A) ▶ Disconnect the cable from the PDB and remove the cable from the clamp (see circles).
  • Page 179 Front panel Installing the left front panel cable Figure 141: Installing the left front panel cable (A) ▶ Carefully shift the front panel cable through the cable duct. ▶ Ensure to connect the labeled side of the cable to the power distribution board (1).
  • Page 180 Front panel Figure 143: Storing the left front panel cable ▶ Place the cable in the space on the side of the fan cage as shown. Concluding steps ▶ Install the left high speed riser module, see "Installing the new high speed riser module"...
  • Page 181: Replacing The Right Front Panel Cable

    Front panel 11.3.2 Replacing the right front panel cable Field Replaceable Unit Hardware: 30 minutes (FRU) Tools: Preliminary and concluding steps: Phillips PH2 / (+) No. 2 Main steps: tool-less Preliminary steps ▶ Shut down all server nodes, see "Shutting down the server" on page ▶...
  • Page 182 Front panel Figure 144: Removing the right front panel cable (A) ▶ Disconnect the cable from the PDB (see circle). Figure 145: Removing the right front panel cable (B) ▶ Pull out the system ID card, unlock it (1), and then pull it out (2). Upgrade and Maintenance Manual CX400 M6...
  • Page 183 Front panel Figure 146: Removing the right front panel cable (C) ▶ Carefully pull the front panel cable out of the cable duct. Installing the right front panel cable Figure 147: Installing the right front panel cable (A) ▶ Carefully shift the front panel cable through the cable duct. ▶...
  • Page 184 Front panel Figure 148: Note on installing the right front panel cable ▶ Ensure to route the right front panel cable properly as shown. Figure 149: Installing the right front panel cable (B) ▶ Insert the system ID card into the chassis. Insert the system ID card into the chassis.
  • Page 185 Front panel Figure 150: Installing the right front panel cable (C) ▶ Connect the cable to the PDB (see circle). Figure 151: Storing the right front panel cable ▶ Place the cable in the space on the side of the fan cage as shown. Concluding steps ▶...
  • Page 186: Thermal Cable

    Front panel ▶ If applicable, install the HDD/SSD modules until slot 6 from the right into the relevant HDD/SSD cage, see "Installing a 2.5-inch HDD/SSD module" on page 114. ▶ If applicable, install all 2.5-inch HDD/SSD dummy modules until slot 6 from the right into the relevant HDD/SSD cage, see "Installing a 2.5-inch dummy module"...
  • Page 187 Front panel ▶ If applicable, remove all 2.5-inch HDD/SSD dummy modules until slot 6 from the left from the relevant HDD/SSD cage, see "Removing a 2.5-inch HDD/ SSD dummy module" on page 113. ▶ "Extending the server enclosure out of the rack" on page ▶...
  • Page 188 Front panel Figure 153: Removing the thermal cable (B) ▶ Remove the thermal cable from the side of the HDD cage along with the rubber bushing (1). ▶ Remove the rubber bushing from the thermal cable (2). Figure 154: Removing the thermal cable (C) ▶...
  • Page 189: Installing The Thermal Cable

    Front panel 11.4.2 Installing the thermal cable Field Replaceable Unit Hardware: 15 minutes (FRU) Tools: Preliminary and concluding steps: tool-less Main steps: Phillips PH2 / (+) No. 2 Installing the thermal cable Figure 155: Installing the thermal cable (A) ▶ Carefully shift the thermal cable through the cable duct. ▶...
  • Page 190 Front panel Figure 156: Installing the thermal cable (B) ▶ Attach the rubber bush to the thermal cable (1). ▶ Insert the thermal cable with the rubber bushing into the HDD cage (2). Figure 157: Installing the thermal cable (C) ▶...
  • Page 191 Front panel Figure 158: Installing the thermal cable (D) ▶ Place the cable into the space on the side of the fan cage as shown (1). Concluding steps ▶ Install the left high speed riser module, see "Installing the new high speed riser module"...
  • Page 192 Front panel Upgrade and Maintenance Manual CX400 M6...
  • Page 193: Cabling

    Cabling 12.1 Safety notes CAUTION ▶ Always hold cables by their connectors when disconnecting them. Never pull on the cable to disconnect cables. ▶ Ensure that none of the cables are scraped, strained or otherwise damaged while replacing system components. ▶...
  • Page 194 Cabling Part number Type A3C40233582 HDD/SSD backplane signal cable A3C40233583 HDD/SSD backplane power cable A3C40233577 Front panel cable (L/R) A3C40233581 Thermal cable Table 9: List of used cables Upgrade and Maintenance Manual CX400 M6...
  • Page 195: Mechanical Overview

    Appendix A 13.1 Mechanical overview 13.1.1 Server enclosure front Front overview with CX2550 M6 server nodes Using CX2550 M6 server nodes, the server enclosure can be equipped with up to 8x 2.5-inch HDD/SSD modules. Figure 160: Configuration with CX2550 M6 server nodes Front panel for server node 2 HDD bays for server node 3 Front panel for server node 4...
  • Page 196: Server Enclosure Rear

    Appendix A Figure 161: Configuration with CX2560 M6 server nodes Front panel for server node 2 HDD bays for server node 3 Front panel for server node 4 HDD bays for server node 2 Front panel for server node 3 HDD bays for server node 1 ID card Front panel for server node 1...
  • Page 197: Server Enclosure Interior

    Appendix A 13.1.3 Server enclosure interior Figure 163: PRIMERGY CX400 M6 interior 2x hot-plug PSUs 4x HDD/SSD cages each with up to 6 4x CX2550 M6 or 4x CX2560 M6 HDD/SSD bays (not visible) Power Distribution Board 2x High speed riser (not visible)
  • Page 198: Connectors And Indicators

    Appendix A 13.2 Connectors and indicators 13.2.1 Server enclosure front 13.2.1.1 Indicators on the front panel Figure 164: Controls on the front panel (QRL left and right) PSU CSS indicator ID indicator FAN CSS indicator Power-on indicator Global Error indicator CSS indicator Enclosure-related indicators PSU CSS indicator (1)
  • Page 199 Appendix A FAN CSS indicator (2) Status Description No critical event detected (CSS component). orange on Prefailure event detected (CSS component). flashing orange CSS component failure detected. Node-related indicators Each server node has a separate operation area marked with the corresponding number.
  • Page 200 Appendix A Status Description blue on The server has been highlighted using ServerView Operations Manager, iRMC web interface or the ID button on the front panel for easy identification. flashing blue The server has been highlighted for easy identification using the iRMC with disabled local VGA output.
  • Page 201: Indicators On Hot-Plug Hdd / Ssd / Pcie Ssd Modules

    An emergency flash of the iRMC firmware is in progress. For more information on the emergency flash of the iRMC firmware, see the "FUJITSU Server PRIMERGY CX2550 M6 / CX2560 M6 Server Node Upgrade and Maintenance Manual". 13.2.1.2...
  • Page 202: Server Enclosure Rear

    Appendix A Error indicator (2) Status Description No HDD/SSD error detected. orange on An HDD/SSD error has been detected. Possible causes: – The drive is defective and needs replacing. – A RAID rebuild process has failed. – The HDD/SSD module has not been inserted correctly. flashing orange HDD/SSD RAID rebuild is in progress.
  • Page 203: Fan Indicators

    Appendix A PSU status indicator (1) Status Description flashing green The server is switched off, but it is connected to the mains (standby mode). green on The server is switched on and operating properly. flashing orange Warning has been detected. The PSU is still running, but failure might be imminent.
  • Page 204: Indicators Of The Server Nodes

    Appendix A FAN indicator (1) Status Description The corresponding fan module has failed. Lights up orange The corresponding fan module is OK. 13.2.2.3 Indicators of the server nodes For the description of the indicators of the server nodes, see the operating manuals of the relevant server nodes.
  • Page 205 Appendix A ▶ "Shutting down the server" on page ▶ "Disconnecting the power cord" on page ▶ Take the system down to its minimum startup configuration. ▶ "Connecting the power cord" on page ▶ "Switching on the server nodes" on page CAUTION ▶...
  • Page 206 Appendix A Upgrade and Maintenance Manual CX400 M6...
  • Page 207: Supplied Documents

    Appendix B 14.1 Supplied documents The following documents are available in this appendix: ● "Screw list for FUJITSU Server PRIMERGY CX2550 M6 / CX2560 M6 Reference Manual" CX400 M6 Upgrade and Maintenance Manual...
  • Page 208 Screw driver / Screw Usage Type Bit insert FRONT PANEL MIDDLE TOP COVER Phillips FAN-CAGE #6-32 PH2 / (+) No.2 EAR-BRACKET HDD/SSD x6 FRONT BEZEL HDD/SSD x4 FRONT BEZEL Phillips POWER DISTRIBUTION BOARD PH2 / (+) No.2 AIR-DUCT(PDB) M3 x 5.5 mm hexagonal cross SW5 BRIDGE BOARD Phillips...
  • Page 209 Phillips RMK(Rear) PH2 / (+) No.2 Phillips RMK(Inner rail) PH2 / (+) No.2 Hexagon BRIDGE BOARD screw #6-32 AIR-DUCT(BRIDGE BOARD) driver SW10 Phillips POWER DISTRIBUTION BOARD KIT PH2 / (+) No.2 Phillips HIGH SPEED RISER PH2 / (+) No.2...

Table of Contents