Braking system
Characteristic
Control unit F000
CAUTION
IN CASE OF SPORADIC FLASHING OF THE ABS WARNING LIGHT (Dorsoduro 750 ABS, SL 750
Shiver ABS) OR WARNING LIGHT+ABS ICON (NA 850 Mana ABS) (ALSO FLICKERING) AND
STORED OR CURRENT ERROR MISSING INDICATIONS, ALL THIS MEANS THAT THERE IS A
BAD CONTACT BETWEEN THE BATTERY POSITIVE LEAD AND PIN 18 OF THE ABS CONTROL
UNIT. CHECK THE TERMINALS, THAT THE 20A FUSE PINS ARE NOT RUSTED AND THE CON-
TINUITY OF THE RED-ORANGE/RED CABLE BETWEEN PIN 18 OF THE ABS CONTROL UNIT
CONNECTOR AND THE BATTERY POSITIVE POLE.
Adjustable parameters screen page
Characteristic
Coding (1)
Coding (2)
Coding (3)
NOTE: the "X" in the table identifies the connector pin is grounded.
CAUTION
A PASSWORD IS REQUIRED.
TO OBTAIN ONE, CONTACT THE TECHNICAL SERVICE.
BRAK SYS - 332
Value/example
Unit of
measure
ment
ADJUSTABLE PARAMETERS
Value/example
Unit of
measure
ment
MSS Mana GT ABS
Notes
hicle identification line - Pins 2-15 of ABS control
unit)
Possible control unit fault
Notes
Used for re-coding the control unit or coding a new
one.
Vehicle identification is done according to the con-
nection of PINS 2 and 15 of the ABS control unit
connector and is stored in the control unit memory.
The identification can be read in the ISO diagram
in the line: Vehicle code.