APRILIA MSS Mana GT ABS Service Station Manual page 133

Table of Contents

Advertisement

MSS Mana GT ABS
Electrical specifications
Gear upshift:
0 Ohm, between PIN 2 and PIN 1
infinite resistance between PIN 2 and
PIN 5
Gear downshift:
0 Ohm between PIN 3 and PIN 8
infinite resistance between PIN 3 and
PIN 4
Pin-out:
Gear upshift:
1 - supply + 12 V (green - black/purple)
2 - ground (black - brown/black)
5 - supply + 12 V (yellow - blue/purple)
Gear downshift:
3 - ground (brown - brown/black)
4 - supply + 12 V (blue - black/yellow)
8 - supply + 12 V (red - blue/yellow)
THE CONNECTION DIAGRAMS ARE IN THE ELECTRICAL SYSTEM SECTIONS; PAY ATTENTION
TO THESE DIAGRAMS AS THEY SHOW THE CONNECTOR/COMPONENT AS VIEWED FROM
THE CABLE HARNESS SIDE, THAT IS LOOKING AT THE CABLES WHEN GOING OUT OF THE
"MAIN" CABLE HARNESS AND INTO THE CONNECTOR/COMPONENT.
CAUTION
BEFORE CARRYING OUT ANY TROUBLESHOOTING, CAREFULLY READ THE GENERAL TROU-
BLESHOOTING CONCEPTS FOR ELECTRICAL DEVICES AT THE BEGINNING OF THE CHECK
AND CONTROL SECTION IN THE ELECTRICAL SYSTEM CHAPTER.
AXONE / AUTOMATIC TRANSMISSION system
STATUSES
Handlebar gear upshift control
Example value: Released/Pressed/Invalid data
If the "Invalid Data" message is displayed, it means that a malfunction has been detected.
Handlebar gear downshift control
Example value: Released/Pressed/Invalid data
If the "Invalid Data" message is displayed, it means that a malfunction has been detected.
ERRORS
Handlebar gear upshift control - Code 900F - signal not valid
Error cause
Electrical system
ELE SYS - 133