Parameter
Parameter description
COHb
CO back pressure in percent
ColBarVol
Volume of collection bar during which CO and He is measured
CO Conc
CO concentration of the DLCO test gas
CVI
Ratio of FEV
Discard Vol
Discard volume
DL
Adjusted CO diffusion capacity for carboxyhemoglobin, hemoglobin, altitude
adj
DL
/VA
Ratio of DL
adj
DLCO
Diffusing capacity of the lung based on CO
DLCO/VA
Ratio of DLCO to VA, also known as KCO
(KCO)
E
/I
Ratio of FEF
50
50
EOTV
End of test volume
ERV
Expiratory reserve volume
f
Breathing frequency
FA CO
Alveolar CO concentration
FA HE
Alveolar He concentration
FE CO
Expiratory CO concentration
FEF
Forced expiratory flow at 10% of vital capacity—synonymous with MEF
10
FEF
Forced expiratory flow at 25% of vital capacity—synonymous with MEF
25
FEF
Forced expiratory flow from 25% to 75% of vital capacity—synonymous with MMEF
25-75
FEF
/FVC
Ratio of FEF
25-75
FEF
FEF
based on FEV
25-75_6
25-75
FEF
Forced expiratory flow at 40% of vital capacity—synonymous with MEF
40
FEF
Forced expiratory flow at 50% of vital capacity—synonymous with MEF
50
FEF
/FVC
Ratio of FEF
50
FEF
/VC
Ratio of FEF
50
max
FEF
Forced expiratory flow at 60% of vital capacity—synonymous with MEF
60
FEF
Forced expiratory flow at 75% of vital capacity—synonymous with MEF
75
FEF
Forced expiratory flow from 75% to 85% of vital capacity
75-85
FEF
Forced expiratory flow at 80% of vital capacity—synonymous with MEF
80
FET
Forced expiratory time
FET
Forced expiratory time between FEF
25-75
FEV
Forced expiratory volume after 0.25 seconds
.25
FEV
Forced expiratory volume after 0.5 seconds
.5
FEV
/FVC
Ratio of FEV
.5
FEV
Forced expiratory volume after 0.75 seconds
.75
FEV
/FEV
Ratio of FEV
.75
6
FEV
/FVC
Ratio of FEV
.75
FEV
/VC
Ratio of FEV
.75
max
 Parameters
Operator's Manual V5.0 • EasyOne Pro/LAB Rev. 05
© ndd Medizintechnik AG • Technoparkstrasse 1, 8005 Zurich, Switzerland • www.ndd.ch
to FIV
.5
.5
to VA—synonymous to Kroghs K
adj
to FIF
50
50
to FVC
25-75
instead of FVC
6
to FVC
50
to VC
50
max
25
to FVC
.5
to FEV
.75
6
to FVC
.75
/VC
.75
max
and FEF
75
Unit
%
L
%mol
L
mL/min/mm Hg
mL/min/mm Hg/L
mL/min/mm Hg
mL/min/mm Hg/L
L
L
1/min
ppm
%mol
ppm
L/s
90
L/s
75
L/s
1/s
L/s
L/s
60
L/s
50
1/s
1/s
L/s
40
L/s
25
L/s
L/s
20
s
s
L
L
L
35
31/171

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for NDD EasyOne Pro

This manual is also suitable for:

Easyone pro lab

Table of Contents