Utilities > Configuration > Test > FVC / FVL
Operator's Manual V5.0 • EasyOne Pro/LAB Rev. 05
© ndd Medizintechnik AG • Technoparkstrasse 1, 8005 Zurich, Switzerland • www.ndd.ch
Type
First, the setting
FVC, Ex. only
bronchial provocation test is performed using an FVC test or an FVL test.
Second, if you have integrated EasyOne Pro/LAB with your EMR system and if
you use the GDT plug-in, the setting
relevant. With this setting, you can configure which test of the two is initiated
when the EMR system requests forced spirometry.
To allow the patient to breathe regularly through the spirette before the
breathing maneuver, choose
when
Manual Test Stop
is selected under
> General > Test
Procedure.
About integration of EMR systems, 41
Test Procedure, 108
End-of-maneuver criteria selection
If you choose the
FVC
option, the measurement continues until the end of test
criteria are met or until you end the test manually. With this setting, all the
intermediate flow values, e.g. MEF
If you choose the
FEV6
option, the measurement stops after six seconds. With
this setting, none of the intermediate flow values, e.g. MEF
reported.
The FVC test determines the forced expiratory vital capacity. The forced
expiratory vital capacity is the maximum volume that the patient can exhale
during the FVC breathing maneuver and is indicated by the FVC value in the
report.
The FEV
value indicates the forced expiratory volume that the patient has
6
exhaled after six seconds.
For diagnostic purposes, the FVC value is comparable with the FEV
advantage of choosing the
fixed duration of six seconds and is less demanding for the patient (see
Ferguson (2000/NLHEP) [4]). The disadvantage is that the intermediate flow
values, e.g. MEF
, FEF
25
25-75
List of bibliographic references, 137
Parameter
To select which diagnostic parameters to include on the test result screens
and on the printed reports, choose
Viewing and printing reports with EasyOne Pro/LAB, 102
Predicted graph
To visualize predicted values in the flow-volume curve and the volume-time
curve on the test result screens and on the printed reports, choose
predicted points
and
Show predicted
or
FVL, Ex./In.
determines whether the
FVC, Ex. only
or
Tidal
Breathing. This check box is only available
Utilities > Configuration > Test
, FEF
, are reported.
25
25-75
FEV6
option is that the FVC test only takes the
, cannot be reported.
Select FVC
and
Select
range.
FVL, Ex./In.
is also
, FEF
, are
25
25-75
value. The
6
FVL.