COMMUNICATION FLEXANALOG™ PARAMETERS

Customizing the communication logic operands

Communication FlexAnalog™ parameters
164
Select the Settings > Configure FlexOperands menu item to open the user-configurable
operands window.
Figure 148: User-configurable communication logic operands window
The left side of this screen displays all operands that are currently available to the D90
The communication logic operands are displayed by selecting the Comms tree item. Each
operand can be renamed with a user-specified value to provide additional information or
match specific applications.
User Configured Event Name
Range: up to 20 alphanumeric characters
Default: ---
Each available communications logic operand can be renamed to a user-specified
value. This feature allows users to rename operands to allow for clearer identification or
to match specific applications. The new operand name will appear in protection and
automation logic, in settings that take operands as their value, and in event reports.
The following communication FlexAnalog™ parameters (analog operands) are available
Plus
for the D90
. They are listed alphabetically by operand syntax The definitions listed
below reflect the programmed source and element names, where applicable.
Real time clock analog operands
Day of Month...............................................Real time clock day of month value
Day of Week.................................................Real time clock day of week value
Day of Year ...................................................Real time clock day of year value
Hour of Day ..................................................Real time clock hour of day value
Minute of Hour............................................Real time clock minutes of hour value
Month of Year..............................................Real time clock month of year value
Second of Minute.......................................Real time clock second of minute value
Year ..................................................................Real time clock year value
GOOSE analog inputs analog operands
GOOSE Analog In 1....................................Metered value for GOOSE analog input 1