Figure 73. Configuring Redundant Layer 2 Pairs without Spanning Tree
You configure a redundant pair by assigning a backup interface to a primary interface with the switchport backup interface
command. Initially, the primary interface is active and transmits traffic and the backup interface remains down. If the primary fails for any
reason, the backup transitions to an active Up state. If the primary interface fails and later comes back up, it remains as the backup
interface for the redundant pair.
If the interface is a member link of a LAG, the following primary/backup interfaces are also supported:
primary interface is a physical interface, the backup interface can be a physical interface
primary interface is a physical interface, the backup interface can be a static or dynamic LAG
primary interface is a static or dynamic LAG, the backup interface can be a physical interface
primary interface is a static or dynamic LAG, the backup interface can be a static or dynamic LAG
In a redundant pair, any combination of physical and port-channel interfaces is supported as the two interfaces in a redundant pair. For
example, you can configure a static (without LACP) or dynamic (with LACP) port-channel interface as either the primary or backup link in a
redundant pair with a physical interface.
To ensure that existing network applications see no difference when a primary interface in a redundant pair transitions to the backup
interface, be sure to apply identical configurations of other traffic parameters to each interface.
If you remove an interface in a redundant link (remove the line card of a physical interface or delete a port channel with the no
interface port-channel command), the redundant pair configuration is also removed.