Dell S6100 Configuration Manual page 945

Hide thumbs Also See for S6100:
Table of Contents

Advertisement

8
Configure the VLT links between VLT peer 1 and VLT peer 2 to the top of rack unit (shown in the following example).
9
Configure the static LAG/LACP between ports connected from VLT peer 1 and VLT peer 2 to the top of rack unit.
EXEC Privilege mode
show running-config entity
10
Configure the VLT peer link port channel id in VLT peer 1 and VLT peer 2.
EXEC mode or EXEC Privilege mode
show interfaces interface
11
In the top of rack unit, configure LACP in the physical ports.
EXEC Privilege mode
show running-config entity
12
Verify that VLT is running.
EXEC mode
show vlt brief or show vlt detail
13
Verify that the VLT LAG is running in both VLT peer units.
EXEC mode or EXEC Privilege mode
show interfaces interface
Example of Configuring VLT
In the following sample VLT configuration steps, VLT peer 1 is Dell-2, VLT peer 2 is Dell-4, and the ToR is S60-1.
NOTE:
If you use a third-party ToR unit, Dell Networking recommends using static LAGs with VLT peers to avoid potential
problems if you reboot the VLT peers.
Configure the VLT domain with the same ID in VLT peer 1 and VLT peer 2.
Dell-2(conf)#vlt domain 5
Dell-2(conf-vlt-domain)#
Dell-4(conf)#vlt domain 5
Dell-4(conf-vlt-domain)#
Configure the VLTi between VLT peer 1 and VLT peer 2.
1
You can configure the LACP/static LAG between the peer units (not shown).
2
Configure the peer-link port-channel in the VLT domains of each peer unit.
Dell-2(conf)#interface port-channel 1
Dell-2(conf-if-po-1)#channel-member TenGigabitEthernet 1/1/4/1-1/1/4/4
Dell-4(conf)#interface port-channel 1
Dell-4(conf-if-po-1)#channel-member TenGigabitEthernet 1/1/4/1-1/1/4/4
Configure the backup link between the VLT peer units.
1
Configure the peer 2 management ip/ interface ip for which connectivity is present in VLT peer 1.
2
Configure the peer 1 management ip/ interface ip for which connectivity is present in VLT peer 2.
Configure the VLT links between VLT peer 1 and VLT peer 2 to the Top of Rack unit. In the following example, port Te 1/1/4/1 in VLT peer 1
is connected to Te 1/1/8/1 of ToR and port Te 1/1/5/1 in VLT peer 2 is connected to Te 1/1/3/1 of ToR.
1
Configure the static LAG/LACP between the ports connected from VLT peer 1 and VLT peer 2 to the Top of Rack unit.
2
Configure the VLT peer link port channel id in VLT peer 1 and VLT peer 2.
3
In the Top of Rack unit, configure LACP in the physical ports (shown for VLT peer 1 only. Repeat steps for VLT peer 2. The bold vlt-
peer-lag port-channel 2 indicates that port-channel 2 is the port-channel id configured in VLT peer 2).
Dell-2#show running-config interface tengigabitethernet 1/1/4/1
!
Virtual Link Trunking (VLT)
945

Advertisement

Table of Contents
loading

Table of Contents