VLT LAG Mode
Peer1
Peer2
Promiscuous
Access
Trunk
Access

Configuring a VLT VLAN or LAG in a PVLAN

You can configure the VLT peers or nodes in a private VLAN (PVLAN). Because the VLT LAG interfaces are terminated on two different
nodes, PVLAN configuration of VLT VLANs and VLT LAGs are symmetrical and identical on both the VLT peers. PVLANs provide Layer 2
isolation between ports within the same VLAN. A PVLAN partitions a traditional VLAN into subdomains identified by a primary and
secondary VLAN pair. With VLT being a Layer 2 redundancy feature, support for configuration of VLT nodes in a PVLAN enables Layer 2
security functionalities to be achieved. This section describe how to configure a VLT VLAN or a VLT LAG (VLTi link) and assign that VLT
interface to a PVLAN.

Creating a VLT LAG or a VLT VLAN

1
Configure the port channel for the VLT interconnect on a VLT switch and enter interface configuration mode
CONFIGURATION mode
interface port-channel id-number.
Enter the same port-channel number configured with the peer-link port-channel command as described in
Creating a VLT
Domain.
NOTE:
To be included in the VLTi, the port channel must be in Default mode (no switchport or VLAN assigned).
2
Remove an IP address from the interface.
INTERFACE PORT-CHANNEL mode
no ip address
3
Add one or more port interfaces to the port channel.
INTERFACE PORT-CHANNEL mode
channel-member interface
interface: specify one of the following interface types:
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the stack/slot/port/subport information.
For a 25-Gigabit Ethernet interface, enter the keyword twentyFiveGigE then the stack/slot/port/subport information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the stack/slot/port[/subport] information.
For a 50-Gigabit Ethernet interface, enter the keyword fiftyGigE then the stack/slot/port/subport information.
For a 100-Gigabit Ethernet interface, enter the keyword hundredGigE then the stack/slot/port information.
4
Ensure that the port channel is active.
INTERFACE PORT-CHANNEL mode
no shutdown
5
To configure the VLT interconnect, repeat Steps 1–4 on the VLT peer switch.
6
Enter VLT-domain configuration mode for a specified VLT domain.
CONFIGURATION mode
PVLAN Mode of VLT VLAN
Peer1
Peer2
- Primary VLAN Y
- Primary VLAN X
Primary
Secondary
Primary/Normal
Secondary
ICL VLAN
Mac
Membership
Synchronization
No
No
No
No
No
No
Virtual Link Trunking (VLT)