Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 1045

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

Severity
Error
User Response
Complete the following steps:
1. Continue booting the system. If the system does not reset, manually reset the system.
2. If the error is not reported on the subsequent boot, no additional recovery action is required.
3. If the error persists, continue booting system and update the UEFI image.
4. (Trained service technician only) Replace the system board.
• S.3818007 The firmware image capsules for both flash banks could not be verified. CRTM image
capsule could not be verified
Explanation:
Severity
Error
User Response
Complete the following steps:
1. If system failed to boot successfully, DC cycle system.
2. If system boots to F1 setup, update the UEFI image and reset bank to primary (if required). If the
system boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if the firmware update attempt fails, (trained service technician only)
replace the system board.
S.51003 An uncorrectable memory error was detected in DIMM slot [arg1] on rank [arg2]. An
uncorrectable memory error was detected on processor [arg3] channel [arg4]. The failing DIMM
within the channel could not be determined. An uncorrectable memory error has been detected.
Fatal Memory Error Occurred
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies
to this memory error.
2. If the node has recently been installed, moved, serviced, or upgraded, verify that the DIMM
is properly seated and visually verify that there is no foreign material in any DIMM connector
on that memory channel. If either of these conditions is found, correct and retry with the same
DIMM. (Note: Event Log may contain a recent 580A4 event denoting detected change in DIMM
population that could be related to this problem.)
3. If no problem is observed on the DIMM connectors and the problem persists, replace the DIMM
identified by LightPath and/or event log entry.
4. If problem re-occurs on the same DIMM connector, swap the other DIMMs on the same memory
channel across channels one at a time to a different memory channel or Processor. (check
Appendix B. UEFI (POST) error codes
1029

Advertisement

Table of Contents
loading

Table of Contents