• S.58008 A DIMM has failed the POST memory test. DIMM Failed Memory Test
Explanation:
Severity
Error
User Response
Complete the following steps:
1. You must AC-cycle the system to re-enable the affected DIMM connector or re-enable manually
using the Setup utility.
2. If the compute node has been recently installed, serviced, moved, or upgraded, check to ensure
that DIMMs are firmly seated and that no foreign material can be seen in the DIMM connector.
If either condition is observed, correct and retry with the same DIMM. (Note: The event Log
might contain a recent 00580A4 event denoting detected change in DIMM population that
could be related to this problem.)
3. If problem persists, replace the DIMM identified by LightPath and/or event log entry.
4. If problem recurs on the same DIMM connector, swap the other DIMMs on the same memory
channel across channels one at a time to a different memory channel or processor. If problem
follows a moved DIMM to a different memory channel, replace that DIMM.
5. Check the Lenovo support site for an applicable service bulletin or firmware update that applies
to this memory error.
6. (Trained service technician only) Remove affected Processor and inspect Processor socket pins
for damaged or mis-aligned pins. If damage is found, or this is an upgrade Processor, replace the
system board. If there are multiple Processor's, swap Processor's to move affected Processor to
another Processor socket and retry. If problem follows the affected Processor (or there is only
one Processor), replace the affected Processor.
7. If problem stays with the original DIMM connector, re-inspect DIMM connector for foreign
material and remove, if found. If connector is damaged, replace system board
• S.68005 An error has been detected by the the IIO core logic on Bus [arg1]. The Global Fatal Error
Status register contains [arg2]. The Global Non-Fatal Error Status register contains [arg3]. Please
check error logs for the presence of additional downstream device error data. Critical IOH-PCI Error
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device and resolve that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the
system or adapter that applies to this error.
3. Replace the I/O device or PCIe adapter
4. (Trained technician only)Replace the system board reported in the error.
• S.680B8 Internal QPI Link Failure Detected. Internal QPI Link Failure Detected
Explanation:
Appendix B. UEFI (POST) error codes
1031