(12) Mirror base wire tension adjustment
Use the mirror base adjustment screw to shift the tension adjustment
plate back and forth and adjust.
When the mirror base B is at the home position, adjust so that the
distance between the notched sections and the mirror base wire
springs are about 4mm. (When the mirror base adjustment screw is
rotated in clockwise, the tension adjustment plate is shifted toward A.
That is, the distance between the notched section and the wire spring
becomes smaller.)
Tension
adjustment plate
A
B
Tension
adjustment screw
Mirror base B notches
Mirror base B notches
Mirror base wire spring
Smm
8 – 18
Mirror base wire
Mirror base wire springs