Sharp SF-2050 Service Manual page 122

Hide thumbs Also See for SF-2050:
Table of Contents

Advertisement

Main
Sub
Item
code
code
44
9
Process control
data display
46
47
Contents
When the sub code is entered, the LCD shows the following
display to allow checking of the output level of the drum mark-
ing sensor and the process control sensor.
SIMULATION NO. 44-9
FVGNOM : nnn
FVGPHT
NVGNOM : nnn
NVGPHT : nnn
FCLNOM : nnn
FCLPHT
NCLNOM : nnn
NCLPHT
FCLAE
: nnn
NCLAE
DVCL
: nnn
DSENSE : nnn
DMCNT
: nnn
IDCNT
TNRNCT : nnn
FVGNOM
Normal mode grid bias initial value
FVGPHT
Photo mode grid bias initial value
FVGTS
Toner save mode grid bias initial value
NVGNOM
Current normal mode grid bias value
NVGPHT
Current photo mode grid bias value
NVGTS
Current toner save mode grid bias value
FCLNOM
Normal mode copy lamp voltage EXP.1 initial
value
FCLPHT
Photo mode copy lamp voltage EXP.1 initial
value
FCLTS
Toner save mode copy lamp voltage EXP.1
initial value
NCLNOM
Current normal mode copy lamp voltage
EXP.1
NCLPHT
Current photo mode copy lamp voltage EXP.1
NCLTS
Current toner save mode copy lamp voltage
EXP. 1
FCLAE
AE mode copy lamp voltage (WH level) initial
value
NCLAE
Current AE mode copy lamp voltage (WH
level)
DVCL
Dirt correction reference lamp voltage
DSENSE
Dirt correction sensor initial value registered
value
DMCNT
Marking sensor gain rank
IDCNT
Process control sensor gain rank
DMRNCT
Film wear correction counter
TNRNCT
Toner controller correction counter value
When the START Key is pressed, process control is executed
and then the exposure adjustment can be performed. For ad-
justment procedure, refer to the exposure adjustment
(separate sheet).
AE sensor output level adjustment.
9 – 29
: nnn
FVGTS
: nnn
NVGTS
: nnn
: nnn
FCLTS
: nnn
: nnn
NCLTS
: nnn
: nnn
: nnn
DMRNCT :
nnn
Adjustment value
Ref. page
Adjustment
Default
scope
P. 8 – 20
P. 8 – 20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf-c52

Table of Contents