Sharp SF-2050 Service Manual page 127

Hide thumbs Also See for SF-2050:
Table of Contents

Advertisement

Main
Sub
Item
code
code
2
Lead edge
adjustment (simple
type)
3
Lead edge
adjustment value
input
Contents
When this simulation is executed, the machine starts warming
up and the LCD shows the following display. The currently set
value of "50_L1" (Lead edge shift at 200% copy) is displayed
on the copy quantity display.
SIMULATION NO. 50-2
INPUT_A (0~999)
Enter the value of "lead edge shift at 200% copy" with the
10-key pad and press the PROGRAM ( P ) key to store it.
Press the scroll key ( → ) to scroll the message display on the
LCD and the copy quantity display as follows:
50_L2 → 50C → 50D → 50E → 50_L1 → 50_L2 →
The set value can be stored or changed in the same manner
as in "50A."
After completion of warming up, copying is allowed.
LCD DISPLAY
COPY QUANTITY DISPLAY
*
* *
: Lead edge shift at 200% copy (L1)(1 count = 0.1mm)
INPUT_L1(0~999)
SCROLL KEY
* * *
: Lead edge shift at 100% copy (L2)(1 count = 0.1mm)
INPUT_L2(0~999)
SCROLL KEY
* * *
:
INPUT_C (1~20)
SCROLL KEY
* * *
: Lead edge void amount data(1 count = 0.47mm)
INPUT_D (0~20)
SCROLL KEY
* * *
: Read edge void amount data (1 count = 0.47mm)
INPUT_E (0~20)
Note 1: ( ) shows the input range of adjustment value.
Note 2: When "50_L1" is entered, the copy magnification ratio
is automatically set to 200%.
[Adjustment procedure]
1. Set L1 and L2 to "0."
2. Put a scale on the original table.
3. Make a copy at 200%.
4. Make a copy at 100%.
5. Set the screen to "INPUT_L1" display, and enter the lead
edge shift at 200% copy with the 10-key pad.
(Example) IN the case of 35.5mm, enter "355."
6. Set the screen to "INPUT_L2" display, and enter the lead
edge shift at 100% copy with the 10-key pad.
(Example) In the case of 35.5mm, enter "355."
7. Press the START key to make a copy.
When the sub code is entered, the LCD shows the following
display and the currently set value of "50A" (distance between
MHP to the image lead edge) is displayed on the copy quantity
display. With the RPL on, enter the set value with the 10-key
pad and press the START key to store it.
SIMULATION NO. 50-3
INPUT_D (0~99)
Press the scroll key ( → ) to scroll the message display on the
LCD and the copy quantity display as follows:
50B → 50C → 50D → 50E → 50A → 50B →
The set value can be stored or changed in the same manner
as in "50A."
9 – 34
Adjustment value
Default
ON
ON
ON
ON
Ref. page
Adjustment
scope
P. 8 – 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf-c52

Table of Contents