Sharp SF-2050 Service Manual page 103

Hide thumbs Also See for SF-2050:
Table of Contents

Advertisement

Main
Sub
Item
code
code
4
Warm-up saving
5
Process operation
check
6
Intermittent
operation aging
(with jam)
7
Intermittent
operation aging
(without jam)
8
Contents
When the sub code is entered, the machine operation can be
checked without warm-up. If the heater section is at low
temperature, the heater low temperature amy be detected and
"H4" may be displayed.
When the sub code is entered, all process operations are
checked.
When the sub code is entered, the LCD shows the following
display. With the RPL on, enter the value with the 10-key pad,
and the set time will be displayed on the copy quantity display.
Press the START key to start warming up. After completion of
warming up, the RPL turns on and aging is performed under
the standby state for the set time.
SIMULATION NO. 7-6
INPUT INTERVAL TIME.
(1~900SEC)
When the sub code is entered, the LCD shows the following
display.
With the RPL on, enter the value with the 10-key pad, and the
set time will be displayed on the copy quantity display. Press
the START key to start warming up. After completion of warm-
ing up, the RPL turns on and aging is performed under the
standby state for the set time. In this case, paper jam is ig-
nored.
SIMULATION NO. 7-7
INPUT INTERVAL TIME.
(1~900SEC)
When the main code is inputted, the LCD shows the following
display and a sub code blinks on the copy quantity display.
With the RPL on, enter the desired sub code and press the
START key to start the operation.
(Except for SUK and Japan)
SIMULATION NO. 8
INPUT 1~7
1. DEVELOPING BIAS VOLTAGE TEST.
2. MAIN HIGE VOLTAGE UNUT TEST.
3. MAIN HIGE VOLTAGE UNUT TEST.
(PHOTO MODE)
4. MAIN HIGE VOLTAGE UNUT TEST.
5. (NO PROGRAM)
6. TRANSFER HIGE VOLTAGE UNUT TEST.
7. SEPARATION HIGE VOLTAGE UNUT TEST.
9 – 10
Adjustment value
Ref. page
Adjustment
Default