Sharp SF-2050 Service Manual page 134

Hide thumbs Also See for SF-2050:
Table of Contents

Advertisement

Main
Sub
Item
code
code
53
1
Original stop
position adjustment
2
Original stop
position adjustment
3
Original stop
position adjustment
4
Original stop
position adjustment
7
RADF resist sensor
adjustment
8
RADF timing
sensor adjustment
9
RADF paper exit
sensor adjustment
Contents
When the main code is inputted, the LCD shows the following
display and a sub code blinks on the copy quantity display.
With the RPL on, enter the desired sub code and press the
START key to start the operation.
SIMULATION NO. 53
01~04: ORIGINAL STOP POINT SETUP.
NOM
THIN
*
1
*
2
*
3
*
4
05~06: (NO PROGRAM)
07~10: RADF SENSOR ADJUSTMENT.
07. REGIST 08. TIMING 09. EXIT/REVERSAL
10. EMPTY
Used to adjust the original (normal paper) stop position in the
RADF in the single copy mode.
Used to adjust the original (normal paper) stop position in the
RADF in the duplex copy mode.
Used to adjust the original (thin paper) stop position in the
RADF in the single copy mode.
Used to adjust the original (thin paper) stop position in the
RADF in the duplex copy mode.
When this simulation is executed, the RPL lights up and the
currently set adjustment value is displayed on the copy quan-
tity display. Enter the set value with the 10-key pad and press
the START key to store it.
The adjustment value range is 0 ∼ 15. With "8" as the refer-
ence value, if the adjustment value is smaller than the refer-
ence value, the stop position comes to the paper feed side. If
the adjustment value is greater than the reference value, the
stop position comes to the paper exit side.
Adjustment value
Adjustment value
0
–8.000mm
1
–7.000mm
2
–6.000mm
3
–5.000mm
4
–4.000mm
5
–3.000mm
6
–2.000mm
7
–1.000mm
8
0.0 (Reference)
9
+1.000mm
10
+2.000mm
11
+3.000mm
12
+4.000mm
13
+5.000mm
14
+6.000mm
15
+7.000mm
(Reference: Adjustment value =8)
Used to adjust the threshold value of the RADF resist sensor
sensing level.
Used to adjust the threshold value of the RADF timing sensor
sensing level.
Used to adjust the threshold value of the RADF paper exit
sensor sensing level.
9 – 41
Default
SIMP
DUP
*
*
*
*
Paper feed side
Paper exit side
Adjustment value
Ref. page
Adjustment
scope