[8] ADJUSTMENTS

1. Developing section

(1) Developing doctor clearance adjustment
1
Disassembly the section until as shown in the figure.
2
Loosen fixing screws A of the DV doctor. (2 pcs. in the rear frame,
2 pcs.in the front frame)
Insert a 0.50mm clearance gauge between 50mm ∼ 80mm from
3
the DV doctor edge.
4
Press the DV doctor in the arrow direction, and tighten the fixing
screw of the DV doctor. (Tighten in the front and the rear sides.)
5
Check that there is a clearance of 0.55
DV doctor edge and at 80mm from the other edge.
@ Note: When inserting the clearance gauge, be careful not to
scratch the DV doctor and the MG roller.
(2) Developing magnet roller main pole position
adjustment
1
Disassemble the section until as shown in the figure.
2
Tie a thread to a needle or a pin.
3
Hold the thread, and bring the needle near the MG roller. (Since
the MG roller diameter is so small that a clip cannot be used for
precise positioning.)
4
Mark the contact point of the needle on the MG roller surface with
a marking pen.
5
Measure the distance between the marked position and the sur-
face on which the developing unit is placed. Check that the dis-
tance is 17.0 ± 0.2mm.
If the distance is not the specified value, loosen the fixing screw of
the main pole adjustment plate, and move the adjustment plate in
the arrow direction to adjust.
17.0±0.2
+0.05
mm at 50mm from the
–0.02
8 – 1
+0.05
0.55
-0.03
A
50mm
30mm
30mm
50mm
A
17.0±0.2
A