Electrical installation
8.3.1

Shielding connection to the front panel

52
02/2017
Remove the outside shroud of the cable
and the shielding braid on the desired core
length. Secure the cores with a cable tie.
Remove the outside shroud of the line on a
length from for instance 30mm without da-
Pull a cable tie by the slot in the shielding
rail on the front panel of the servo amplifier.
Press the shielding of the cable firmly
against the front panel with the cable tie.
Use the shield clamp that is delivered with
the motor cable for the shield connection of
the motor cable. The clamp must be hoo-
ked in the lower shroud and guarantees op-
timal contact between shield and shroud.