3.4

Decommissioning

Only professional staff who are qualified in electrical engineering are allowed to decom-
mission parts of the drive system.
DANGER
electrical shock or electrical arcing.
l
l
l
l
3.5

Maintenance and cleaning

The device does not require maintenance. Opening the device voids the warranty. The
inside of the unit can only be cleaned by the manufacturer
Do not immerse or spray the device. Avoid that liquid enters the device.
To clean the device exterior:
1. Decommission the device (see chapter 3.4).
2. Casing: Clean with isopropanol or similar cleaning solution.
3. Protective grill on fan: Clean with a dry brush.
3.6

Disassemble

Only professional staff who are qualified in electrical engineering are allowed to disas-
semble parts of the drive system.
1. Decommission the device (see chapter 3.4).
2. Check temperature.
3. Remove the connectors. Disconnect the potential earth connection last.
4. Demount: loosen the fastening screws. Remove the device.
S300 Instructions Manual
: Lethal voltages! There is a danger of serious personal injury or death by
Switch off the main switch of the switchgear cabinet.
Secure the system against restarting.
Block the main switch.
Wait at least 5 minutes after disconnecting.
CAUTION
: Highly Flammable! Risk of injury by explosion and fire.
- Observe the safety notes given on the cleaning liquid package.
- Wait at least 30 minutes after cleaning before putting the device back into
operation.
CAUTION
: High Temperature! Risk of minor burns.
During operation, the heat sink of the drive may reach temperatures above
80 °C (176 °F). Before touching the device, check the temperature and wait until it
has cooled below 40 °C (104 °F).