Remove the outer covering of the
cable and the shielding braid from
the cores for the required length.
Secure the cores with a cable tie.
Remove the outer covering of the
cable over a length of about 30mm,
without damaging the shielding
braid.
Pull a cable tie through the slot in
the shielding rail (front panel) of the
servo amplifier.
Use the cable tie to clamp the
shielding braid of the cable firmly
to the shielding rail.