Behavior In The Event Of An Error (With Standard Setting) - Kollmorgen SERVOSTAR 300 Instruction Manual

Digital servo amplifier
Hide thumbs Also See for SERVOSTAR 300:
Table of Contents

Advertisement

Technical description
6.7.2

Behavior in the event of an error (with standard setting)

The behavior of the servo amplifier always depends on the current setting of a number of
different parameters (ACTFAULT, VBUSMIN, VELO, STOPMODE, etc.; see
Some faults (see
immediately, independent from the
by uncontrolled coasting of the load. An additional mechanical brake is
required for functional safety, which must be safely operated.
The diagram shows the startup procedure and the procedure that the internal control
system follows in the event of motor overtemperature, assuming that the standard param-
eter settings apply. Fault F06 does not switch-off the output stage immediately, with
ACTFAULT=1 a controlled emergency brake is started first.
24V
BTB/RTO
Main Power
DC-Bus
Power Stage
enable
F06
Motor Speed
STO-ENABLE
ENABLE
extern
(F06 = error messages "Motor Temperature")
Even if there is no intervention from an external control system (in the example, the
ENABLE signal remains active), the motor is immediately braked using the emergency
stop ramp if the error is detected and assuming that no changes have been made to the
factory setting (ACTFAULT=1).
34
CAUTION
ERRCODE
Start
Boot-Time
> 100ms
02/2017
) force the output stage to switch-off
ACTFAULT
Standard Operation
~500ms
Kollmorgen
setting. Danger of injury
Fault Motor Temperature
VELO
S300 Instructions Manual
online
help).