Canopen Interface (X6) - Kollmorgen SERVOSTAR 300 Instruction Manual

Digital servo amplifier
Hide thumbs Also See for SERVOSTAR 300:
Table of Contents

Advertisement

Electrical installation
8.17

CANopen interface (X6)

The interface for connection to the CAN-bus (default : 500 kBaud). The integrated profile
is based on the CANopen DS301 communication profile and the DS402 drive profile.
The following functions are available in connection with the position controller:
Jogging with variable speed, homing run (zeroing to reference), start motion task, start
direct task, digital setpoint provision, data transmission functions and many others.
Detailed information can be found in the CANopen manual. The interface is at the same
electrical potential as the RS232 interface. The analog setpoint inputs can still be used.
With the optional -2CAN- expansion card, the two interfaces for RS232 and CAN, which
otherwise use the same connector X6, are separated out onto three connectors (with ter-
mination, ð p.129).
CAN-bus cable
To meet ISO 11898, a bus cable with a characteristic impedance of 120 W should be
used. The maximum usable cable length for reliable communication decreases with
increasing transmission speed. As a guide, you can use the following values which we
have measured, but they are not to be taken as assured limits:
Cable data:
Cable length, depending on the transmission rate
Transmission rate (kBaud)
Lower cable capacitance (max. 30 nF/km) and lower lead resistance
(loop resistance, 115 W/km) make it possible to achieve greater distances.
(Characteristic impedance 150 ± 5 W Þ terminating resistor 150 ± 5 W).
For EMC reasons, the SubD connector housing must fulfill the following requirements:
Master
CANL
CANH
GND
Shield
96
S300
X6
9
6
CAN
+5V
5
* according to line impedance
AGND
Characteristic impedance
Cable capacitance
Lead loop resistance
1000
500
250
— metal or metalized housing
— provision for cable shielding connection on the housing, large-area connection
X6
* according to line impedance about 120W
02/2017
120 *
Ù
CANH
CANL
AGND
CAN ref. to ISO 11898
100-120 W
max. 60 nF/km
159.8 W/km
max. cable length (m)
10
70
115
X6
CANL
CANH
GND
Kollmorgen
CAN-Server/Client
CANL
CANH
GND
Shield
S300 Instructions Manual
CAN
X6