Install Water Inlet Pipe - Toyota 3VZ–FE Troubleshooting Manual

Table of Contents

Advertisement

ENGINE TROUBLESHOOTING
(c) Install the water inlet with the three nuts.
Torque: 20 N m (200 kgf cm, 14 ft lbf)
3.

INSTALL WATER INLET PIPE

(a) Install a new O–ring to the water inlet pipe.
(b) Apply soapy water to the O–ring.
(c) Connect the water inlet pipe to the water inlet.
(d) Install the bolt holding the water inlet pipe to the generator
belt adjusting bar.
Torque: 20 N m (200 kgf cm, 14 ft lbf)
4.
INSTALL TIMING BELT (See page EG–29)
5.
CONNECT RADIATOR LOWER HOSE
6.
CONNECT CABLE TO NEGATIVE TERMINAL OF
BATTERY
7.
FILL WITH ENGINE COOLANT (See page EG–244)
COOLING SYSTEM