Endress+Hauser Proline Prosonic Flow B 200 Operating Instructions Manual page 19

Ultrasonic transit time flowmeter
Hide thumbs Also See for Proline Prosonic Flow B 200:
Table of Contents

Advertisement

Proline Prosonic Flow B 200 HART
Endress+Hauser
C
Horizontal orientation, transmitter
head down *
D
Horizontal orientation, transmitter
head at side
* A maximum deviation of only ±3° is permitted for the horizontal alignment of the
converters.
Inlet and outlet runs
If possible, the sensor should be installed upstream from valves, T-pieces, elbows etc. To
attain the specified level of accuracy of the measuring device, the below mentioned inlet
and outlet runs must be maintained at minimum. If there are several flow disturbances
present, the longest specified inlet run must be maintained.
Single-path version: DN 50 (2"), DN 80 (3")
1
20 × DN
20 × DN
3
 4
Single-path version: minimum inlet and outlet runs with various flow obstructions
1
90 ° elbow or T-section
2
Pump
3
2 × 90 ° elbow, 3-dimensional
4
Control valve
Orientation
–3°
+3°
3 × DN
2
20 × DN
3 × DN
20 × DN
4
Installation
Compact version
A0015590
A0015592
–3°
+3°
3 × DN
3 × DN
A0016534
A0015453
19