Endress+Hauser Proline Prosonic Flow B 200 Operating Instructions Manual page 112

Ultrasonic transit time flowmeter
Hide thumbs Also See for Proline Prosonic Flow B 200:
Table of Contents

Advertisement

Diagnostics and troubleshooting
112
Available status signals
Configuration as per HART 7 Specification (Condensed Status), in accordance with
NAMUR NE107.
Symbol
Meaning
Failure
A device error has occurred. The measured value is no longer valid.
A0013956
Function check
The device is in service mode (e.g. during a simulation).
A0013959
Out of specification
The device is operated:
• Outside its technical specification limits (e.g. outside the process temperature range)
• Outside of the configuration carried out by the user (e.g. maximum flow in parameter
A0013958
20 mA value)
Maintenance required
Maintenance is required. The measured value remains valid.
A0013957
Has no effect on the condensed status.
A0023076
12.5
Overview of diagnostic information
The amount of diagnostic information and the number of measured variables affected
increase if the measuring device has one or more application packages.
In the case of some items of diagnostic information, the status signal and the
diagnostic behavior can be changed. Change the diagnostic information →  111
Diagnostic
Short text
number
Diagnostic of sensor
022
Temperature sensor
082
Data storage
083
Memory content
104
Sensor signal path 1 to
2
105
Transducer
105
Transducer
105
Transducer
105
Transducer
Proline Prosonic Flow B 200 HART
Remedy instructions
1. Check temperature sensor cable
2. Change main electronic module
3. Change sensor
1. Change main electronic module
2. Change sensor
1. Restart device
2. Restore S-Dat data
3. Change sensor
1. Check process conditions
2. Clean transducer
3. Change transducer
1. Check transducer 2 cable
2. Change transducer 2
1. Check transducer 3 cable
2. Change transducer 3
1. Check transducer 4 cable
2. Change transducer 4
1. Check transducer 1 cable
2. Change transducer 1
Status
Diagnostic
signal
behavior
[from the
[from the
factory]
factory]
F
Alarm
F
Alarm
F
Alarm
F
Alarm
F
Alarm
F
Alarm
F
Alarm
F
Alarm
Endress+Hauser